PYLE Audio PT501 instruction manual Lubrication, Maintenance

Models: PT501

1 8
Download 8 pages 38.51 Kb
Page 6
Image 6

Place tool in forward or reverse position. Push button in on “F” side for forward or “R” side for reverse.

Push button all the way in on the “F” side for Forward position.

Push button all the way in on the “R” side for Reverse position.

Depress the trigger to operate tool.

Release trigger to stop tool.

Always disconnect air supply when changing sockets.

When job is complete, turn the air compressor off and store as described in the air compressor operator manual.

MAINTENANCE

Lubrication

Air tools require lubrication throughout the life of the tool. The air motor and bearing uses compressed air to power the tool. Because moisture in compressed air will rust the air motor, you must lubricate the motor daily. An inline oiler is recommended.

To lubricate the air motor manually:

1.

Disconnect the tool from the air supply

 

 

holding it so the air inlet faces up.

 

2.

Depress the trigger and place one to two

 

 

drops of air tool oil in the air inlet

 

 

Depressing the trigger helps circulate oil in

 

 

the motor. NOTE: Use SAE #10 weight oil if

Button

 

air tool oil is not available.

3.Connect the tool to an air source, cover the exhaust end with a towel and run for a few seconds.

 

 

 

 

Any excess oil in the

Trigger

 

 

 

 

 

 

 

 

 

 

 

 

motor is immediately

Air Inlet

 

 

 

 

expelled from the exhaust port. Always

Torque

direct exhaust port away from people or

objects.

Regulator

 

 

 

 

Failure to lubricate the

 

 

 

 

 

 

tool at the air inlet will void your warranty.

D22725

6- ENG

Page 6
Image 6
PYLE Audio PT501 instruction manual Lubrication, Maintenance