Environmental Specifications

1–Product Overview Adapter Specifications

Environmental Specifications

Table 1-1. Environmental Specifications

Condition

Operating

Non-Operating

 

 

 

Temperature Ranges

10°C to 55°C a

–40°C to 65°C

(for Altitude=900 m or 2952.75 ft)

(50°F to 131°F)

(–40°C to 149°F)

 

 

 

 

Temperature Ranges

10°C to n°C b

–40°C to 65°C

(for Altitude >900 m or 2952.75 ft)

(50°F to n°F c)

(–40°F to 149°F)

 

 

 

Temperature Gradient Maximum

10°C

20°C

per 60 Min.

 

 

 

 

 

Humidity Percent Ranges—Non-

20% to 80%

5% to 95%

condensing

(Max Wet bulb temper-

(Max Wet bulb tempera-

 

ature= 29°C) d

ture= 38°C)d

 

 

 

Humidity Gradient Maximum

10%

10%

per 60 Min.

 

 

 

 

 

Altitude Ranges—Low Limits

–15.2m (–50 ft)

–15.2m (–50 ft)

 

 

 

Altitude Ranges—High Limits

3,048m (10,000 ft)

10,668m (35,000 ft)

 

 

 

Airborne Contaminants—ISA-71

G1d

G1d

Level

 

 

 

 

 

a200LFM is required to operate at this temperature.

bUse the following formulas to calculate the maximum operating temperature (in °C) for a specific altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.

cUse the following formulas to calculate the maximum operating temperature (in °F) for a specific altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.

dMaximum corrosive contaminant levels measured at =50% relative humidity; see Table 3 in

ISA-71.04-1985.