Flow control = XON/XOFF

Step 2. Power up the switch.

Step 3. To change the switch default IP address enter:

setChassisIpAddr -h ipaddress -m netMask

where -h ipaddress is the new IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format, and -m netMask is the new subnet mask in dotted decimal (i.e., xxx.xxx.xxx.xxx) format.

Step 4. To change the switch default gateway IP address enter:

setDefaultRoute -h ipaddress

where -h ipaddress is the new default gateway IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format.

Using Telnet or SSH

Step 1. Power up the switch.

Step 2. Connect a Category 5 or 6 (Cat 5/6) Ethernet cable to the RJ-45 connector on the switch. Connect the other end of the Cat 5/6 to a OOB LAN workstation.

Step 3. Access the switch with the following command:

telnet 192.168.100.9

Step 4. The system prompts for a user name. In order to change the IP address and default gateway, the user must be logged in as the administrator. At the prompt enter:

admin

Step 5. The system prompts for a password. At the prompt enter:

adminpass

The system responds with:

Welcome to the SilverStorm 9120 CLI. Type 'list' for the list of commands.

Step 6. To change the switch default IP address enter:

setChassisIpAddr -h ipaddress -m netMask

5

Page 7
Image 7
Q-Logic 9120 To change the switch default gateway IP address enter, System prompts for a password. At the prompt enter