| Setting Up the |
SF-3 Factory-installed SIPs
fHP= 30 Hz (27 kΩ SIP resistor in J2)
fLP= 250 Hz (22 kΩ SIP resistor in J6)
SF-3 Factory Switch Settings
When shipped from the factory, the DIP switch settings should be set as follows:
Switches 1 through 6 and Switch 10 OFF: Default setting for
Switches 7 & 8 ON:
Switch 9 OFF: LF flat
SF-3 Recommended Amplifier Settings
Clip limiters ON (both channels)
Operating mode: Stereo or Bridge mode, as the application requires
Use this table to determine the correct | Identifying SIP resistor networks | |
resistor values for the | ||
SIP resistor value |
| |
80 Hz | 68K |
|
150 Hz | 39K |
|
250 Hz | 22K |
|
SIP resistor value |
| |
20 Hz | 47K |
|
25 Hz | 33K |
|
30 Hz | 27K |
|
35 Hz | 20K |
|
40 Hz | 15K |
|
50 Hz | 10K |
|
11