Rigging the Installation Line Array (continued)
Table 1: ILA Working Load Limits
Component | Weight | 5:1 Design Factor | 7:1 Design Factor | 10:1 Design Factor |
|
|
|
|
|
|
|
|
|
|
38 lb (17.3 kg) | 2400 lb(1090.0 kg) | 1714 lb (779.2 kg) | 1200 lb (545.5 kg) | |
|
|
|
|
|
17 lb (7.7 kg) | 1036 lb (470.9 kg) | 740 lb (336.4 kg) | 518 lb (235.5 kg) | |
|
|
|
|
|
6 lb (2.7 kg) | 296 lb (134.5 kg) | 211 lb (96.1 kg) | 148 lb (67.3 kg) | |
|
|
|
|
|
37 lb (16.8 kg) | 889 lb (403.2 kg) | 634 lb (288.3 kg) | 445 lb (201.8 kg) | |
|
|
|
|
|
111 lb (50.5 kg) | 1036 lb (470.9 kg) | 740 lb (336.4 kg) | 518 lb (235.5 kg) | |
|
|
|
|
|
M8 Shoulder Bolt1 | not applicable | 1404 lb (638.2 kg) | 1003 lb (455.8 kg) | 702 lb (319.1 kg) |
M8 | not applicable | 2534 lb (1151.8 kg) | 1810 lb (822.7 kg) | 1267 lb (575.9 kg) |
M12 Shoulder Bolt1 | not applicable | 6641 lb (3018.8 kg) | 4744 lb (2156.3 kg) | 3321 lb (1509.4 kg) |
3/8” Fastener1 | not applicable | 2721 lb (1236.7 kg) | 1943 lb (883.4 kg) | 1360 lb (618.4 kg) |
7/8” Fastener1 | not applicable | 11354 lb (5161.0 kg) | 8110 lb (3686.4 kg) | 5677 lb (2580.5 kg) |
1- Working Load Limits are per fastener loaded in double shear. Data is for informational purposes only.
Attaching WL2082-i to Array Frame
Before beginning any installation, have your system designer configure the array with proper splay angles using QSC’s EASE Focus (Array Calculator). All orientation of product is to be as
viewed from the rear of the enclosure. | Figure 7: |
| |
Attach the array frame to the suspension structure using a 3/4” (20 mm) screw pin anchor |
|
shackle and appropriate sling, cable, etc.... |
|
For arrays of 4 |
|
included mating hardware. Ensure the notched rigging plate is on the right hand side (the sys- |
|
tem can only be installed one way. Note the QSC logo on the input plate will be right side up |
|
when the enclosure is oriented properly). During assembly, ensure your splay angles are as |
|
desired. |
|
When constructing large arrays it is recommended to first assemble units of four enclosures |
|
and then assemble the final array by joining the four enclosure units to one another. |
|
Attachment of one enclosure to another is accomplished by inserting the |
|
bolt with washer through the rigging plate attachment holes and appropriate splay angle |
|
selection holes in the mating rigging plates and threading the lock nut (nylock) on the inside |
|
edge of the plates. The bolt should be tightened snuggly to no more than 5 |
|
| |
Attach the array frame to the top enclosure by inserting the |
|
washer through the appropriate mounting holes and threading the lock nut (nylock) on the |
|
inside edge of the plates. The bolt should be tightened snuggly to no more than 5 |
|
of torque. |
|
NOTE: For some array configurations, use of the extension bar and/or |
|
may be required to achieve the required aiming angle. |
|
7