Quadra-Fire 1900 owner manual Mobile Home Installation, Outside Air Kit Installation

Models: 1900

1 14
Download 14 pages 20.68 Kb
Page 14
Image 14
MOBILE HOME INSTALLATION
Part #831-1300

FIGURE 13

EXTERIOR CHIMNEY RUNNING UP

THE OUTSIDE OF THE RESIDENCE

*Note: Unit has not been tested with a horizontal connector. Refer to local building codes.

MOBILE HOME INSTALLATION

You must use a Quadra-Fire 1900 outside air kit (see page 15 for part numbers) for installation in a mobile home. Use of alternative material will void warranty.

1.

An outside air inlet must be provided for combustion and be unrestricted while unit is in use.

2.

Unit must be secured to the mobile home structure by bolting pedestal through hearth pad and into floor.

 

For leg models, use attachment brackets to attach stove through pad and into floor.

3.

Do not install unit in a sleeping room.

4.

The structural integrity of the mobile home floor, walls, and ceiling/roof must be maintained (i.e., do not

 

cut through floor joist, wall stud, ceiling truss, etc.).

5.

Unit must be grounded with #8 copper grounding wire or equivalent and terminated at each end with

 

N.E.C. approved grounding device.

6.

Refer to clearance to combustibles section (page 6) for listing to combustibles.

OUTSIDE AIR KIT INSTALLATION

1900 LEG MODELS

1. Remove ¼"-20 screws from stove bottom.

2.Mount front cover over the front air intake with two ¼"-20 screws.

3.Mount intake fitting on underside of bottom pan, and connect to ducting.

4.Floor installation: Cut a 4" (101mm) minimum hole in the floor to accommodate outside air piping. Use 4" (101mm) metal flex or rigid piping to directly connect outside air to the unit or into vented crawl space. Use the rodent screen supplied to cover the hole in the floor. Seal between the floor and the pipe with silicone to prevent moisture penetration.

5.Rear/wall installation: Cut a 4" (101mm) hole in outside wall to accommodate outside air piping. Use 4" (101mm) metal flex or rigid piping to directly connect outside air to stove intake. Use a termination cap equipped with a rodent screen (obtain from venting manufacturer). Seal between the wall and the pipe with silicone to prevent moisture penetration.

Intake fitting

Front cover

Front cover

 

 

 

Floor mounting bracket

1900 PEDESTAL MODELS

Part #831-1750

1.Front cover plate attaches to firebox bottom below ashlip with two ¼”-20 screws supplied.

2.Mount rear cover plate with four mounting screws supplied. This cover will seal the pedestal (floor installation) or have a 4" (101mm) hole (rear installation).

3.Both kits have two 1” (25mm) rope gaskets to be tucked under pedestal to seal off both sides.

4.Floor installation: Cut a 4" (101mm) minimum hole in the floor to accommodate outside air piping. Use 4" (101mm) minimum metal flex or rigid pipe to directly connect outside air to the unit or into vented crawl space. Use the rodent screen supplied to cover the hole in the floor. Seal between the floor and the pipe with silicone to prevent

moisture penetration.

3.Rear/wall installation: Cut a 4" (101mm) hole in outside wall to accommodate outside air piping. Use a 4" (101mm) metal flex or rigid piping to directly connect outside air to stove intake. Use a termination cap equipped with a rodent screen (obtain from venting manufacturer). Seal between the wall and the pipe with silicone to prevent moisture penetration.

7.

Seal all wall/floor inlets to prevent air or moisture penetration. Check periodically to insure the inlet is free

 

of obstructions (e.g., snow or ice).

8.

Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide).

9.

If unit burns poorly while exhaust blower is on in home, increase combustion air.

NOTE: Offsets from the vertical, not exceeding 45°, are allowed per Section 905(a) of the Uniform Mechanical Code (UMC). Offsets greater than 45°are considered horizontal and are also allowed, providing the horizontal run does not exceed 75% of the vertical height of the vent. Construction, clearance and termination must be in compliance with the UMC Table 9C. This installation also complies with NFPA 211.

Rear inlet (wall)

Rear cover (floor)

OUTSIDE AIR KIT INSTALLATION Rodent screen

Rope gasket

Page 14

Page 15

Page 14
Image 14
Quadra-Fire 1900 owner manual Mobile Home Installation, Outside Air Kit Installation