CB 1200 Pellet Stove

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Mobile Home

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Mobile Home Installation

 

 

 

 

 

 

 

 

CAUTION

 

 

 

You must use a Quadra-Fire Outside Air Kit

 

 

 

 

 

 

 

 

 

 

for installation in a mobile home.

Maintain structural integrity of mobile home:

 

 

 

 

• Floor, wall, ceiling and/or roof.

 

 

1. An outside air inlet must be provided for the combustion

Do NOT cut through:

 

 

air and must remain clear of leaves, debris, ice and/or

• Floor joist, wall, studs or ceiling trusses.

 

 

snow. It must be unrestricted while the appliance is

• Any supporting material that would affect the structural

 

 

in use to prevent room air starvation which causes

integrity.

 

 

smoke spillage. Smoke spillage can also set off smoke

 

 

 

 

 

 

 

alarms.

 

 

 

 

 

 

 

2. The combustion air duct system must be made of

 

 

 

 

 

 

 

 

CAUTION

 

 

metal. It must permit zero clearance to combustible

 

 

construction and prevent material from dropping into

 

Never draw outside combustion air from:

 

the inlet or into the area beneath the dwelling and

 

• Wall, floor or ceiling cavity

 

contain a rodent screen.

 

• Enclosed space such as an attic or garage

 

3.

The appliance must be secured to the mobile home

 

 

 

structure by bolting it to the floor (using lag bolts).

 

 

 

Use the same holes that secured the appliance to the

 

 

 

shipping pallet.

 

Spark Arrestor Cap

4.

The appliance must be grounded with #8 solid copper

 

 

 

 

grounding wire or equivalent, terminated at each end

 

 

 

with an NEC approved grounding device.

 

 

5.

Refer to Clearances to Combustibles and floor pro-

Storm Collar

 

 

tection requirements on pages 8 & 9 for listings to

 

Roof Flashing

 

combustibles and appropriate chimney systems.

 

6.

Use silicone to create an effective vapor barrier at

 

 

 

the location where the chimney or other component

 

 

 

penetrates to the the exterior of the structure.

 

 

7.

Follow the chimney manufacturer’s instructions when

Joist Shield/Firestop

 

 

installing the vent system for use in a mobile home.

Approved Class “L” o

 

 

8.

Installation shall be in accordance with the Manufactur-

 

“PL” Pellet Vent

 

 

 

ers Home & Safety Standard (HUD) CFR 3280, Part

 

 

 

24.

 

 

 

WARNING

 

 

Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

WARNING

Never install in a sleeping room.

Figure 16.1

Page 16

7014-082D

September 1, 2008