B. Clearances to Combustibles (UL and ULC)

CB 1200 Pellet Stove

R

B. Clearances to Combustibles (UL and ULC)

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

44

1117

A

B

CAlcove InstallationStraight Back Against

C

Minimum Alcove Width

40-1/2

1029

Maximum Alcove Depth

36

915

Minimum Alcove Side Wall

6

152

Top of Unit to Combustibles

12-1/2

318

Wall WARNING

Straight Back Against

Inches

Millimeters

Wall

 

 

 

A

 

Back Wall to Appliance

2

51

B

 

Side Wall to Appliance

6

152

 

 

 

Corner Installation

Inches

Millimeters

C

 

Walls to Appliance

2

51

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

Fire Risk.

Comply with all minimum clearances to combustibles as specified.

Failure to comply may cause house fire.

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

D

F

 

 

E

G Corner Installation

G

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Top

6

152

F

Back Wall to Appliance

7.5

191

 

 

 

Corner Installation

Inches

Millimeters

G

Walls to Appliance

2

51

Page

7014-082D

September 1, 2008

Page 8
Image 8
Quadra-Fire CB1200-B B. Clearances to Combustibles UL and ULC, Alcove Installation, Straight Back Against, Wall