Quadra-Fire QVI-25FB-S owner manual B. Junction Box Installation, C. Installation for Fan Optional

Models: QVI-25FB-S

1 39
Download 39 pages 29.23 Kb
Page 18
Image 18
B. Junction Box Installation

B. Junction Box Installation

 

 

SIDE

 

 

WALL

 

INSERT RELIEF

 

 

AROUND CORD IN THIS END

 

 

FROM OUTSIDE OF UNIT

 

FEED PLUG

 

THROUGH HOLE

JUNCTION

 

 

BOX

Figure 9.2

Junction box installation

 

Optional Accessories

Connecting the electrical junction box is required if using a blower or remote.

Plug the cord into a convenient outlet.

An electrician may install an outlet box inside the fireplace. Place the outlet in the lower, back corner of the fireplace.

Must use cord supplied.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Optional Accessories WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

C. Installation for Fan (Optional)

On units already installed removal of decorative front, surround and gas insert is required.

Detach flexible liner from back of unit if insert is installed.

Remove the four screws on the cover plate (see Figure 9.3).

 

FAN

RUBBER

COVER

GROMMETS

PLATE

 

ATTACH

 

GROUND WIRE

Figure 9.3

 

Bend up the tabs on the base pan (see Figure 9.4).

Place the blower in between the bend up tabs.

Install and wire the blower per instruction shipped with the fan.

The ground wire of the fan can clip on the side of the base pan.

Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration.

18

Quadra-FireQVI-25FB-S2031-910 Rev. D • 3/08

Page 18
Image 18