3 Fireplace Size Requirements

3 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements are shown in Figure 3.1.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built firebox in order to gain minimum gas insert opening requirements.

Ε Any smoke shelves, shields, baffles and the metal floor of the unit may be removed from a factory built firebox if attached with mechanical fasteners. If the appliance is placed on the base of the outer wrap, a ¼ inch airspace must be provided between the insert and the floor of the outer wrap.

Ε Cutting of any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited.

A. Minimum Fireplace Opening WARNING

Fire Risk

Provide adequate clearance:

Around air openings

To combustibles

• For service access

Locate appliance away from traffic areas.

NOTE: For actual appliance dimensions refer to Section 15.

20-3/8 in.

14-7/16 in.

29-3/4 in.

15 in.

1-1/16 in.

18-15/16 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-9/16 in.

 

 

 

 

 

 

 

 

 

(GAS BALL VALVE NOT SHOWN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXISTING MINIMUM WOODBURNING FIREPLACE SIZE

 

 

 

 

 

 

 

 

 

Location

Inches

 

Millimeters

 

 

 

 

 

A

Front Width

30-7/8

 

 

 

784

 

 

 

 

 

 

 

B

Rear Width

25-5/8

 

 

 

651

 

 

 

 

 

 

 

C

Depth

15

 

 

 

381

 

 

 

 

 

 

 

D

Height

19-1/2

 

 

 

495

 

 

*NOTE: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum fireplace height for bends in vent pipe.

Figure 3.1 Fireplace Opening