Quadra-Fire QVI-25FB-S Vent Information and Diagrams, A. Vent Table Key, B. Horizontal Venting

Models: QVI-25FB-S

1 39
Download 39 pages 29.23 Kb
Page 9
Image 9
5 Vent Information and Diagrams

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

VMIN

Minimum Vertical Run Length 14 ft.

VMAX

Maximum Vertical Run Length 50 ft.

B. Horizontal Venting

Horizontal venting is NOT allowed.

C. Measuring Standards

Vertical measurements listed in the vent diagram (Figure

5.1) were made using the following standard:

• Vertical terminations are measured to top of chimney.

A. Vent Table Key WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION

ALL vent specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

TERMINATION

 

CAP

 

FLASHING

 

INLET AIR COLLAR

 

EXHAUST COLLAR

 

EXHAUST

 

VENT PIPE

 

V= 14 FT. MINIMUM

 

50FT. MAXIMUM

 

3 INCH COLLAR

 

(Factory installed to

 

stainless steel section)

 

WARNING: DO NOT

 

BLOCK PIPE END WITH

 

INSULATION OR ANY OTHER

 

SEALING MATERIAL

 

STAINLESS STEEL

 

PIPE - 3 FT. MIN.

 

REQUIRED (INCLUDED)

 

SEAL DAMPER

 

AREA

 

INLET AIR

 

VENT PIPE

 

COLLAR ATTACHMENT

 

BRACKET

 

Figure 5.1

 

Quadra-FireQVI-25FB-S2031-910 Rev. D • 3/08

9

Page 9
Image 9
Quadra-Fire QVI-25FB-S Vent Information and Diagrams, A. Vent Table Key, B. Horizontal Venting, C. Measuring Standards