47
Characteristics (continued)
0
IP 67 modular I/O splitter boxes
for fieldbuses 0
Advantys Distributed I/O, FTM splitter boxes

Digital input/output splitter box characteristics
Splitter box type Inputs Inputs/outputs
Compact FTM1DE08Cpp FTM 1DE16C12 FTM1DD08Cpp FTM 1DD16C12
Expandable FTM1DE08CppEFTM 1DE16C12E FTM1DD08CppEFTM 1DD16C12E
Number of inputs/outputs 8I 16I 8I/O 16I/O
Internal consumption of splitter box mA 30 (M8)
50 (M12)
50 30 (M8)
50 (M12)
50
Operating voltage c V 24
Splitter box max. supply current A4
Auxiliary supply max. current A4 (only
FTM1DD16C12)
Bus and I/O undervoltage detection V<18

Input characteristics

Number of inputs 8I 16 I 0...8I 0...16I
Conformity to IEC1131-2 Type 2
Compatibility with 2-wire/3-wire
proximity sensors
Yes
Input values Nominal voltage c V 24
Maximum current mA 200
Sensor power supply V18...30
Logic Positive
Input filtering ms 1
Channel status indication By LED (yellow), one LED per input
Protection against reversed polarity Yes

Output characteristics

Number of outputs 0...8O 0...16O
Output type Transistor
Nominal output values Voltage c V 24
Current A0.5
Response time ms <0.5
Max. switching cycle Hz Resistive: 50
Inductive: 5
Max. lamp load W10
Channel status indication By LED (yellow), one LED per output
Output connection/cable lengths 0.34 mm2 / 5 m (#22 AWG / 16.4 ft.) max
0.75 mm2 / 10 m (#19 AWG / 32.8 ft.) max
Analog input/output splitter box characteristics
Splitter box type Inputs Outputs
Compact FTM1AE04C12C FTM1AE04C12T FTM1AS04C12C FTM1AS04C12T
Number of inputs/outputs 4I 4I 4O 4O
Internal consumption of splitter box mA 50
Operating voltage c V 24
Maximum supply current Splitter box A4
Per channel A0.2 1.6
Bus and I/O undervoltage detection V<18

Input and output characteristics

Type Differential 300 ΩDifferential 1 MΩ ≤ 500 Ω ≥ 500 Ω
Current Measuring range 0 to 20mA, 4 to
20mA
c±10V, c0 to
10V
0 to 20mA, 4 to
20mA
c±10V, c0 to
10V
Resolution Bits 16 15 + Sign 12 11 + Sign
Conversion time ms 2/channel 1/channel
Input filtering ms 1 –
Channel status indication By LED
Output connection/cable lengths m (ft.) 30 (98.4) max.
Digital and analog splitter boxes diagnostic characteristics
Internal bus and I/O undervoltage detection V<18
Internal bus communication By LED
Channel and splitter box short-circuit By LED
Cable breakage By LED
Presentation, functions:
pages 36 - 41 Description:
page 43 Connections:
pages 44, 45 References:
pages 48, 49 Dimensions, schemes: