Self-adjusting Maintenance Charge (not applied to PAG Li-Ion batteries).

2.7Self Test Program:

The internal microcomputer constantly monitors the battery under charge or process as well as the operation of the charger’s own functions which will be shut down to a safe condition should any of the tests fail.

2.8Camera Power Supply (Models 9752 & 9753 only):

These models feature a power supply rated 13.5V to 15V DC, 3.7A (50W nominal), and is intended for powering a camera only. Connector: XLR-4 (F), pin 1 negative, pin 4 positive.

2.9Mains Input:

100-250V~. Frequency 47-63 Hz. Maximum power consumption 100W.

2.10Output:

26V DC 4A peak.

2.11Output Protection:

Charger protected against short circuit, open circuit, excess battery voltage and reverse battery voltage.

2.12AC Mains Failure Protection:

Should mains failure occur during a charging program, or whilst the charger is connected, it will shut down to a safe condition.

2.13User Interface:

The backlit LCD screen has a display area of 64mm x 15mm, which displays 2 lines of text, with 16 characters per line.

The front panel incorporates a soft function switch for the selection of programs and interrogation of charge data.

2.14Safety:

Designed to comply with electrical safety standard EN60065 and UL6500. NOTE: U.K. mains leads are fitted with a 1" fuse to BS1362 rated 5A as standard.

2.15European Union Directives:

Complies with the following EU Directives:

U5047A PAG QUASAR INSTRUCTION MANUAL

EMC Directive 89/336/EU.

Low Voltage Directive 73/23/EU.

2.16Operating Temperature Range: 0ºC to 40ºC (+32ºF to +104ºF).

2.17Overall Dimensions: Models 9726 & 9752:

72mm high x 135mm wide x 185mm deep (2.8" x 5.3" x 7.3" approx.).

Models 9727 & 9753:

80mm high x 135mm wide x 185mm deep (3.1" x 5.3" x 7.3" approx.).

2.18Weight:

Models 9726 & 9752: 882g (1.94lbs approx.).

Models 9727 & 9753: 844g (1.86lbs approx.).

SECTION 3

INSTALLATION

3.1All Quasar chargers are fitted with a mains input socket conforming to CEE22 (IEC socket). This is situated on the back panel. Mains supply connection to the charger should only be made using the standard lead supplied with this equipment.

3.2Quasar chargers have been designed for use on AC mains supplies worldwide, and automatically accept supplies in the range 100-250V ~. Mains supply frequency must be in the range 47-63 Hz.

3.3Quasar chargers may be operated from a vehicle 12V battery using the PAG Vehicle Battery-Power Converter, Model No. 9774.