7.6 Termination Resistors

Line termination resistors are provided for the input signals of each of the DSCLP-200/300's RS-422/485 ports. Termination may be selected or removed for individual signal lines using jumper blocks J1-J4.

RS-422 Rt = 100 ohm 1/2W

RS-485 Rt = 120 ohm 1/2W

RS-422/485 Receiver

+

 

RXD+

AUXIN+

Rt

 

 

or

-

 

RXD-

AUXIN-

 

 

 

 

 

Jumpers J1-J4

3

3

3

2

2

2

1

1

1

no termination

RS-422 termination

RS-485 termination

 

(100 ohms)

(120 omhs)

(factory default)

Figure 25 --- RS-422/485 Line termination resistance values