Radio Shack Two-Zone Burglar Alarm System Plug the AC adapter into a standard AC outlet

Models: Two-Zone Burglar Alarm System

1 20
Download 20 pages 13.16 Kb
Page 15
Image 15
3.Plug the AC adapter into a standard AC outlet.

49-454.fm Page 15 Wednesday, January 17, 2001 10:37 AM

2.Connect a test lamp to Terminals 15 and 16 on the alarm center. This lamp lets you see if the alarm siren and/or security strobe will work.

Caution: You must use a lamp that uses 12 volts and is rated at 1A or less. Using a lamp that does not meet these specifications could damage the alarm center or the lamp.

3.Plug the AC adapter into a standard AC outlet.

Caution: To prevent electric shock or fire hazard, use only the supplied AC adapter to power the alarm center.

ARMED on the keypad and AC on the alarm center light, BATT and READY flash to indicate an exit delay (since the alarm system is in the process of arming). If they light or flash, go to Step 4.

If the indicators do not light or flash, unplug the AC adapter and make sure:

The fuse inside the alarm center is not blown. If it is, replace it (see “Replacing the Fuse” on Page 19) and repeat this step.

The AC adapter’s wires are connected correctly to Terminals 18 and 19. If they are not, connect them correctly (see “Connecting AC Power” on Page 14) and repeat this step.

The AC outlet has AC power. If it does not, restore AC power and repeat this step.

RESET on the AC adapter is not popped out (indicat- ing an overload). If it is, correct the overload, press RESET completely back inside the AC adapter (see “Resetting the AC Adapter’s Circuit Breaker”), and repeat this step.

4.Unplug the AC adapter.

5.If you installed the backup battery, connect the black battery lead inside the alarm center to the battery’s neg- ative (–) terminal, then connect the red battery lead to the positive (+) terminal.

Caution: Make sure the battery is connected correctly inside the alarm center. Improper installation might cause the fuse inside the alarm center to blow, prevent the alarm system from operating during an AC power failure, and damage the battery and the alarm system.

Important: For proper operation, make sure the alarm center’s door is closed before plugging in the AC adapter.

6.Plug in the AC adapter. AC on the alarm center lights. READY flashes. If READY flashes, go to Step 8.

If READY does not flash, one or more of the loops of sensors is not connected properly, or one or more of the sensors has been activated. Make sure all sensors are in their normal states (either normally open or normally closed) on the same loop. If they are not, connect them correctly (see “Connecting Sensors into Loops” on Page 13 and “Connecting Loops of Sensors to the Alarm Center” on Page 13).

If READY is still off, check the loops as follows:

Normally-Open Loops — Disconnect the wires from Terminals 1 and 5. If READY lights, one of the nor- mally open loops (either in the Instant Zone or Delayed Zone) is not wired correctly. Reconnect the wires for each group in each loop separately to deter- mine which loop is not wired correctly.

Normally-Closed Loops — Connect a short piece of wire between Terminals 2 and 3, then connect another between Terminals 3 and 4. If READY lights, one of the normally closed loops (either in the Instant Zone or Delayed Zone) is not wired correctly.

7.Arm the alarm center by using any connected keypad to enter the password (1234 is the default password) then press ARM once, or simply press ARM twice. Make sure ARMED on the keypad is on.

Note: You cannot arm the alarm center if any loops remain activated. If any of the loops were activated when the alarm system was turned on, ARMED will be off, indicating that the alarm center did not arm because of the loop violation.

8.Check the loops installed in the Delayed Zone.

Turn DELAY TIME ADJ to 55, then set off any sensor installed in the Delayed Zone.

The pre-alarm sounder connected to Terminals 13 and 14 begins to sound and continues sounding for 55 sec- onds during the entry delay time. ARMED starts blinking.

After the entry delay time expires, the lamp you con- nected to Terminals 15 and 16 (alarm siren and light) lights for 4 minutes.

Disarm the alarm system by entering 1 2 3 4 (the default password) then pressing CANCEL on a keypad until ARMED stops blinking.

Reset the sensor you set off above. READY lights.

9.Press ARM twice so ARMED lights.

10.Check the loops installed in the Instant Zone.

Set off any sensor installed in the Instant Zone. READY turns off, ARMED blinks, and the lamp you connected to Terminals 15 and 16 (alarm siren and light) lights for 4 minutes.

Disarm the alarm system by entering 1 2 3 4, then press- ing CANCEL on a keypad until ARMED stops blinking.

Reset the sensor you set off.

11.Check the sensors installed in the Panic/Tamper Zone.

Disarm the alarm system by entering 1 2 3 4, then set off any sensor installed in the Panic/Tamper Zone. READY turns off, the alarm center arms, ARMED blinks, and the lamp you connected to Terminals 15 and 16 (alarm siren and light) lights for 4 minutes.

Reset the sensor you just set off, then disarm the alarm system by entering the password.