Test the panic function of each installed remote keypad by holding down ENTER and CANCEL. The alarm center arms, ARMED blinks, and the lamp you connected to Terminals 15 and 16 (alarm siren and light) lights for 4 minutes.
12.Disarm the alarm system by entering 1 2 3 4, then hold down SETUP for 2 seconds. ARMED and READY flash slowly. Enter the password. ARMED and READY flash quickly. Press ANNC once. ARMED and READY turn off.
To enter announce mode, press ENTER. READY flashes 3 times. To exit announce mode, press CANCEL. READY flashes 3 times.
13.Hold down BATT TEST on the alarm center for 2 sec- onds. If BATT on the alarm center does not light, the backup battery is OK.
If BATT flashes:
•Check the fuse on the alarm center. If it is blown, see “Replacing the Fuse” on Page 19 and repeat this step.
•The backup battery might have insufficient power. Check the battery connections. If the connections are OK, the battery will be automatically recharged. If it does not recharge, replace it promptly.
14.Arm the alarm system by entering 1 2 3 4, then pressing ARM. Then disarm by entering the duress code, 1 2 3 5. The security dialer is triggered.
15.Use a
16.Disconnect the lamp from Terminals 15 and 16, then connect the alarm siren’s and/or light’s negative
Your security system is ready to use!
Operation
ARMING THE SYSTEM
To arm the system, use any connected keypad to enter the password then press ARM once, or simply press ARM twice.
If you enter the correct password and there are no activated or faulted zones, ARMED on the keypad lights, and the alarm system is armed. If you enter the wrong password, the sys- tem does not arm.
Notes:
•While entering the password, if you enter an incorrect digit before entering the last digit, you can press CAN- CEL to cancel your previous entries, then enter the password again.
•When you use a connected keypad, all other keypads are locked out for 10 seconds after the last key press.
DISARMING THE SYSTEM
To disarm the system normally, use any connected keypad to enter the password while the system is armed.
Note: When the system is in exit delay mode, press CAN- CEL to disarm the system.
If you enter the correct password, ARMED on the keypad turns off, and the alarm system is disarmed. If you enter the wrong password, the system remains armed, but gives no indication a wrong code was entered.
Note: If you enter the wrong password three times in a row, the alarm center locks out all connected keypads for 5 min- utes. This prevents an intruder from easily determining your password by trying random combinations.
If your alarm system was activated while it was armed and the alarm sounded, ARMED on the keypad flashes to show that the alarm had sounded. To stop the alarm, enter the password. To stop ARMED from flashing, press CANCEL.
If your alarm system was activated and the alarm sounds, enter the duress code to disarm the system. The alarm stops, but the security dialer still sends the emergency mes- sage. To stop the security dialer, enter the password.
If the system is armed, opening the front cabinet or taking the alarm center off the wall triggers the alarm. Make sure to disarm the system before you open the cabinet or remove the alarm center from the wall.
SOUNDING A PANIC ALARM
You can activate the alarm system’s panic alarm at any time, even if the system is not armed.
To sound a panic alarm, press any installed panic button (if you installed a panic/tamper zone) or press ENTER and CANCEL at the same time on any remote keypad. The alarm sounds and the system automatically arms.
CHANGING THE PASSWORD
Arm or disarm the alarm center by using the number keys on the remote keypad to enter a
Follow these steps to enter a new password.
1.If the alarm center is armed, use the keypad to enter the current password or 1 2 3 4 (the default password). The alarm center is disarmed.
16 |