Accuracy and Range: 2–56 m/s ..............................................................................................

±16°F (±8°C)

Resolution ....................................................................................................................

................. 2°F (1°C)

Rainfall

 

Daily and Cumulative Measurement Display Range ................................................

0–394 in (0–9999 mm)

Rainfall Rate Measurement Display Range ....................................................

0–39.32 in/hr (0–998 mm/hr)

Daily Rainfall Accuracy:

 

Range: <.6 in (15 mm) .....................................................................................

±0.04% in (1 mm) ±1 unit

Range: 0.6–394 in (15–9999 mm) ........................................................................................

±5% ±1 unit

Cumulative Rainfall Accuracy:

 

Range: <.8 in (20 mm) ..........................................................................................

±.04 in (1 mm) ±1 unit

Range: .8 to 394 in (20 to 9999 mm) ....................................................................................

±5% ±1 unit

Rainfall Rate Accuracy:

 

Range: <.6 in/hr (15 mm/hr) ...........................................................................................

±.04 in/hr (±1%)

Range: .6 to 39.32 in/hr (15 to 998 mm/hr) ..........................................................................

+7% ±1 unit

Daily and Cumulative Resolution .............................................................................................

.04 in (1 mm)

Rainfall Rate Resolution ..................................................................................................

.04 in/hr (1 mm/hr)

Daily Sampling Cycle Frequency ...................................................................................................

24 Hours

Rainfall Rate Sampling Cycle Frequency ............................................

Varies Based on Rainfall Frequency

Cumulative Sampling Cycle Frequency ..............................................

Varies Based on Rainfall Frequency

Barometric Pressure

 

Display Range .................................................................................................................

... 600mb–1050mb

Accuracy ......................................................................................................................

..................... ± 10mb

General

 

Display ..........................................................................................................................

Liquid Crystal (LCD)

Clock Accuracy ................................................................................................................

. ±0.5 seconds/day

Power Requirement ..........................................................................................................................

12V DC

Battery Life (Alkaline) .............................................................................................................

About 1 Week

Monitor Dimensions (HWD) ......................................................

81/16 51/2 1 9/16 in (204 139 39 mm)

Weight:

 

Monitor (without batteries) ..................................................................................................

17.81 oz (505 g)

Specifications are typical; individual units might vary. Specifications are subject to change and improvement without notice.

Specifications

35