the last memory reset), press OUT . Then repeatedly press ￿￿￿￿￿￿. ￿￿￿ or ￿￿￿ appears when the monitor shows the maximum or minimum recorded temperature. The recorded times of the maximum or minimum temperatures and ￿￿￿￿￿ also appear.

To reset the temperature records in memory and record a new maximum or minimum temperature beginning with the current read- ing, hold down ￿￿￿￿￿￿ until a beep sounds.

Using the HI/LOW Outdoor Temperature Alarms

You can set the monitor to sound an alarm when a set high or low outdoor temperature is reached.

Each time the temperature changes and meets or exceeds an alarm condition, the current temperature and ￿￿ or ￿￿ flash, and the monitor sounds an alarm for about 1 minute. To silence the alarm sooner, press any key.

Note: If you press a key to silence the alarm, the alarm stops sounding but the current temperature and ￿￿ or ￿￿ continue to flash until that alarm condition is no longer met.

To view the current temperature and the current high or low outdoor temperature alarm

conditions, press OUT and repeatedly press ￿￿￿￿￿. ￿￿ or ￿￿ appears when the monitor shows the high or low indoor temperature alarm condition.

Setting a HI/LOW Temperature Alarm

1.Press OUT , then repeatedly press CHANNEL until ￿￿￿ appears.

2.Repeatedly press ALARM so either ￿￿ or ￿￿ appears.

3.Hold down SET until the last tempera- ture alarm condition flashes.

4.Repeatedly press (or hold down) or to set the temperature alarm.

5.Press SET to store the setting.

Note: The monitor automatically displays the high temperature alarm setting after you set the low alarm temperature and vice versa.

Clearing a HI/LOW Temperature Alarm Setting

To clear the conditions for a high or low temperature alarm so the alarm does not sound, repeatedly press ALARM to select a high or low temperature condition and repeatedly

press until ￿￿￿￿ appears.

Viewing the Outdoor Dew Point and Wind Chill Temperature

Your weather station determines the current dew point and wind chill temperatures from the current collected data. To toggle between the outdoor dew point temperature view and wind chill temperature view, repeatedly press OUT until ￿￿￿ or ￿￿￿￿ ￿￿￿￿￿ appears.

Note: The weather station determines the wind chill temperature when it receives wind speed signals from the anemometer.

Setting the Outdoor Dew Point/ Wind Chill Temperature Alarm

You can set the monitor to sound an alarm when the outdoor dew point is within a specific range (from 2–29°F or 1–16°C) of the current dew point temperature, or when the wind chill temperature meets or drops below a set temperature.

Each time the outdoor dew point temperature changes and is within the programmed range, ￿￿￿ flashes and the monitor sounds an alarm for about 1 minute. To silence the alarm sooner, press any key.