Each time the outdoor wind chill temperature changes and meets or drops below the set temperature, and the current readings flash and the monitor sounds an alarm for about 1 minute. To silence the alarm sooner, press any key.
Note: If you press a key to silence the alarm, the alarm stops sounding, but and the current readings continue to flash until the alarm condition is no longer met.
1.Repeatedly press OUT until or
appears.
2.Press ALARM. appears when you set the dew point temperature alarm, or
appears when you set the wind chill temperature alarm.
3.Hold down SET until the dew point set- ting or the current wind chill setting flashes.
4.Repeatedly press (or hold down) or to set the dew point or wind chill alarm condition.
5.Press SET to store the setting.
Notes:
•If you do not press any button for about 60 seconds, the monitor returns to the current temperature display. To continue programming the settings, start over at Step 2.
•You can only set the wind chill alarm on the outside () channel.
Clearing the Outdoor Dew Point or Wind Chill Temperature Alarm Setting
To clear the dew point or wind chill alarm conditions so the alarm does not sound, repeatedly press OUT until
appears. Press ALARM, then press so
appears.
VIEWING AND RESETTING MAX/MIN RELATIVE HUMIDITY RECORDS
The weather station samples the indoor and outdoor humidity and determines the relative humidity percentage. The current indoor () and outdoor () relative humidity () conditions are located under the indoor and outdoor temperature windows, respectively.
Note: You can also view the indoor relative humidity from the indoor thermo/hygro/baro sensor.
To view the maximum or minimum indoor or outdoor relative humidity recorded since the last memory reset, press the desired %RH (indoor or outdoor), then repeatedly press
until or appears. The recorded times of the maximum or minimum humidity and appear.
To reset the maximum or minimum relative humidity records in memory and record a new record (beginning with the current condi- tion), hold down for about 2 seconds until the monitor beeps.
Using the HI/LOW Relative Humidity Alarms
You can set the monitor to sound an alarm when a set high or low indoor or outdoor relative humidity condition is reached.
Each time the relative humidity changes and meets or exceeds an alarm condition, or
flashes, and the monitor sounds an alarm for about 1 minute. To silence the alarm sooner, press any key.
Note: If you press a key to silence the alarm, the alarm stops sounding, but and the current readings continue to flash until that alarm condition is no longer met.
Operation | 23 |