ISTALLATION

INSTALLATION

3) Electrical Connection

This appliance must be installed by a qualified electrician to comply with the relevant Institute of Electrical Engineers (I.E.E.) regulations and also the local electricity supply company requirements.

WARNING: THIS APPLIANCE MUST BE EARTHED

Make sure that the mains characteristics (voltage, nominal, power, etc.) match the ratings indicated on the data plate on the hob base.

The appliance must be connected to an efficient earthing circuit. If the electricity network is not equipped with an earth connection, then it must be installed separately in compliance with local regulations. Earthing is a safety measure required by law, and must be performed with particular care by a qualified technician, who must also check that the electricity supply characteristics are correct.

We disclaim all responsibilities for not observing these points.

-If the appliance is not equipped with an input cable, connect to the terminal block with an adequate section cable keeping the “earth” conductor longer than “live” ones, see fig. 10.

Fig. 10

The appliance must be connected to the correct electrical supply as stated on the voltage label on the cooker, through a suitable cooker control unit incorporating a double pole switch having a contact separation of at least 3mm in all poles. It must not be connected to an ordinary power socket.

The “earth“ cable does not have to be interrupted by the switch.

Recommended cable type:

Rubber H05 RR_F of minimum 2.5 mm2 conductor size for single phase.

The unit must be protected by a suitable fuse or circuit breaker.

Important:

These products are designed and built according to the European standards EN 60 335-1 and EN 60 335-2-6 and relevant amendments.

The appliance has been produced to the European Directives:

-CEE 89/336 + 92/31 + 93/68 concerning EMC.

-CEE 73/23 + 93/68 concerning the electrical safety.

4) Multiphase connection

Before beginning any servicing always disconnect the electricity supply.

The appliance is supplied for single phase electrical supply. It can be converted for use on a 3 phase supply by changing the connection jumpers.

a)Take off the connection panel by removing the fixing screws by screws (see fig. 11).

Fig. 11

Fig. 12

b)Reposition the connection jumpers as shown in fig. 12.

c)Connect the input cable and hold in place with the cable clamp.

d)Replace the cover panel using the fixing screws (see fig. 11).

6