Activated charcoal filter (Recirculation version)

Activated charcoal filter (Recirculation version)

The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on.

Alarm signal activation

In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off.

Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.

Restore the connection by pressing and holding T1.

Release the button. All five LEDs are turned on.

Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:

-LED flashes twice - Activated charcoal filter saturation alarm ENABLED.

-LED flashes once - Activated charcoal filter saturation alarm DISABLED.

 

REPLACING THE ACTIVATED CHARCOAL FILTER

 

 

Alarm signal reset

 

 

Switch off the lights and extractor motor.

B

A

Press button T3 for at least 3 seconds, until the leds start to

 

flash.

 

 

Replacing the Filter

Remove the metal grease filters

Remove the saturated activated carbon filters as shown (A).

Fit the new filters (B).

Replace the metal grease filters.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

Remove the light cover by unfastening the screws that hold it.

Extract the lamp from the Support.

• Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.

• Replace the light cover.