Control Panel

USE

Control Panel

The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.

KEY

LED

FUNCTIONS

L

0/1 Light

Turns lighting on and off.

T1

0/1 Motor on

First speed.

 

 

When pressed for about 1 seconds the motor

 

 

is switched off.

L

T1

Flashing

24h Changeover

 

This is enabled by pressing and holding

 

the button for approximately 5".It al-

 

lows a suction level of 100 m3/h with a

 

noise level of just 28dB(A).Can be en-

 

abled at any speed, even with the hood

 

turned off.To disable, press and hold

 

the button for approximately 5".

T2

T3

T4

S1

T2

Speed

on

Second speed.

 

Flashing

 

Delay (30')

 

 

 

 

 

 

Press the button for approximately 2" to enable auto-

 

 

 

matic shutdown with a 30' delay. Suitable to complete

 

 

 

elimination of any residual smells. Can be enabled at

 

 

 

any speed and is disabled by pressing the button T1

 

 

 

briefly.

 

 

 

T3

Speed

on

Third speed.

T4

Speed

Fixed

Max. speed

 

 

 

 

 

Flashing

Intensive speed.

 

 

 

Suitable for the strongest cooking vapours and odours.

 

 

 

The function becomes active when the button is

 

 

 

pushed for about 2 seconds. After 10 minutes of func-

 

 

 

tioning it turns off automatically. This function can be

 

 

 

interrupted by means of pressing any of the buttons.

 

S1

Led

Fixed

Indicates that the Metal grease filters saturation alarm

 

 

 

has been triggered, and the filters need to be washed.

 

 

 

The alarm is triggered after 100 working hours. (Re-

 

 

 

set; check the Maintenance-paragraph)

 

 

 

Flashing

indicates that the activated charcoal odour filter

 

 

 

saturation alarm has been triggered, and the filter has

 

 

 

to be replaced; the metal grease filters must also be

 

 

 

washed.

The activated charcoal odour filter is

 

 

 

triggered after 200 working hours. (Activation and

 

 

 

Reset; check the Maintenance-paragraph)

 