![Mounting the hood body](/images/new-backgrounds/70367/7036713x1.webp)
Mounting the hood body
•Open the ducting panels.
•Disconnect the panel from the hood canopy by slid- ing the fixing pin lever.(A)
•Remove the metal grease filters by turning the han- dles provided.
•Adjust the two screws Vr, on brackets 11a, to a mini-
mum.(B)
• Hook the hood canopy onto the two brackets 11a.
• From inside the hood canopy, adjust the screws Vr to set the Hood Canopy level.
• Tighten the safety screw 11.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125 mm, the choice of which is left to the installer.
•To install a ø 125 mm air exhaust connection, insert the reducer flange 9 on the hood body air outlet and the adapting ring
•Fix the pipe in position using sufficient pipe clamps (not supplied).
•Remove any activated charcoal filters.
RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional charcoal filter kit must be purchased.
16
•Remove the chimney angle bracket.
•Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5).
•Fix the air outlet grid 8 on the recirculation air outlet using the 2 screws 12d (2,9 x 9,5) provided.
(A )
ø150
9
8
Vr
( B )
ø 125
10
12d
12c
EN |
| 7 |