Control panel

USE

Control panel

A B C D EF G H I L

Key

Function

Display

A

Upper panel closed: when pressed for about one sec-

Indicates the selected speed.

 

ond it opens the upper panel. It switches the motor on

 

 

at the latest selected speed.

 

 

Upper panel open: when shortly pressed it switches

 

 

the motor on/off.

 

B

Decreases the suction speed.

Number of lit LEDS decreases.

C

Increases the suction speed.

Number of lit LEDS increases.

D

Functioning only when the upper panel is open. This

I flashes and all the LEDS on the display

 

speed has been timed at 10 minutes. After that time

are lit.

 

the system activates automatically the latest selected

By pressing the key the function is deacti-

 

speed. The function is suitable for cooking conditions

vated.

 

when vapours and smells are of the utmost emission.

 

E

Functioning only when the upper panel is open. By

24–symbol appears and the LEDS on the

 

pressing this key it is possible to set up the motor to a

display go off cyclically, one by one.

 

suction speed at 100 m3/h .

By pressing the key the function is deacti-

 

 

vated.

F

Functioning only when the motor is on. By pressing

A flashing clock symbol appears.

 

this key it is possible to set the delayed shutdown of

By pressing the key the function is deacti-

 

the motor and the lighting to 30 minutes.

vated.

G

By pressing this key for about 2 seconds it is possible

A drop symbol indicates that the metal

 

to reset the filter saturation alarm.

grease filters saturation alarm has been

 

 

activated, and the filters need to be

 

 

washed. The alarm is triggered after 100

 

 

working hours.

 

 

C indicates that the charcoal filter satura-

 

 

tion alarm has been activated, and the filter

 

 

has to be replaced. The alarm s triggered

 

 

after 200 working hours.

H

By pressing this key the intensity of the lighting sys-

 

 

tem can be modified up to five levels.

 

I

Upper panel closed: when pressed for about 1 second

 

 

it opens the upper panel and sets the lights at the

 

 

maximum intensity.

 

 

Upper panel open: when shortly pressed it switches

 

 

the lights on/off.

 

L

Upper panel closed: when pressed for about one sec-

 

 

ond it opens the upper panel and switches the motor

 

 

on at the third speed and the lights at the maximum

 

 

intensity.

 

 

Upper panel open: when pressed for about 1 second it

 

 

switches off motor and lights resetting every activated

 

 

function, and closes the upper panel.

 

Keyboard lock: it is possible to jam the keyboard when, for example, cleaning the glass. The motor and lights are switched off, and upper panel can be open or closed.

By pressing the F-key (Delay) for about 5 seconds the keyboard block can be activated or de- activated. This function is confirmed by a Beep and by moving motor LEDS on display.

EN

 