Rangemaster RGG77 Conversion to LPG Gas, Injectors, Tap Adjustment, Affix Label, Pressure Testing

Models: RGG77

1 20
Download 20 pages 18.77 Kb
Page 14
Image 14
WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

6. Conversion to LPG Gas

DocNo.071-0002 - LP gas conversion - BI hobs

Fig.6-1

����������������������������������������

Check in the ‘Technical Data’ section at the back of the instructions that the cooker is convertible to the gas you want to use.

This conversion must be performed by a suitably competent person, in accordance with these instructions and with the local supply company requirements.

Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.

The conversion instructions must be used in conjunction with the rest of the appliance instruction, in particular for information on Standards, cooker positioning, connection, hose suitability, etc.

When servicing or replacing gas-carrying components, disconnect from the gas before starting, and check that the appliance is gas sound after completion.

Do not use reconditioned or unauthorised gas controls.

Disconnect from the electricity supply before commencing servicing.

Before electrical reconnection, check that the appliance is electrically safe.

Injectors

Remove burner caps and heads. Remove the old jets. Fit the new jets (see Technical Data section at the back of the book for correct jets). Reassemble in the reverse order.

Tap Adjustment

Disconnect from the electricity supply.

Pull off all the control knobs. Insert a suitable small flat screwdriver into the hole in the end of the control spindle, and turn the bypass screw on each control clockwise to the stop (Fig.6-1). Refit the control knob.

Affix Label

Stick the LP gas label over the natural gas part of the appliance data label.

Pressure Testing

Make sure that the appliance is gas sound; refer to ‘Pressure Testing’ earlier in the section.

Check the operation of all the burners.

12

Page 14
Image 14
Rangemaster RGG77 manual Conversion to LPG Gas, Injectors, Tap Adjustment, Affix Label, Pressure Testing