Rangemaster U109923 - 05 manual Control Centre Power Down, Error Codes, Door Ajar Alarm

Models: U109923 - 05

1 24
Download 24 pages 24.98 Kb
Page 9
Image 9
Control Centre Power Down

Control Centre Power Down

After 30 seconds the digital display on the control panel will switch off until such time as the refrigerator is used again.

Error Codes

In the event of an error occurring, the main control digital display screen will show one of the following codes:

F1, F2, F3, F5, F6, Ed, ER, E0, E1, E2.

If this happens, please contact Customer Service to have the refrigerator repaired.

Door Ajar Alarm

If any door is left open for more than 60 seconds the Door Ajar Alarm function will start. An alarm will buzz at 30-second intervals to alert the user that a door has been left open.

Over-voltage Protection

This refrigerator is equipped with power-surge protection. When this function is in effect, the refrigerator will switch off automatically. After 5 minutes, the power should be turned back on.

Power-breaking Memorising Function

When the refrigerator turns off as a result of a power surge, the state of the refrigerator before the power break is memorised. Once restarted, this allows the refrigerator to operate with the programmed default values as before the power break.

7

Page 9
Image 9
Rangemaster U109923 - 05 manual Control Centre Power Down, Error Codes, Door Ajar Alarm, Over-voltageProtection