Raypak 195A, 135A, 090A Receiving Equipment, General Specifications, Specifications And Dimensions

Models: 090A 135A 195A

1 28
Download 28 pages 38.36 Kb
Page 3
Image 3
1. RECEIVING EQUIPMENT

1. RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged report the damage to the carrier immediately. Be sure that you receive the number of packages indicated on the Bill of Lading. Claims for shortages and damages must be filed with carrier by consignee.

Purchased parts are subject to replacement only under the manufacturer's warranty. Debits for defective replacement parts will not be accepted and defective parts will be replaced in kind only per our standard warranties.

When ordering parts, you must specify Model and Serial Number of the heater. When ordering under warranty conditions, you must also specify date of installation.

Raypak recommends that this manual be re- viewed thoroughly before installing your Raypak Heater. If there are any questions which this manual does not answer, please contact your local Raypak representative.

2. GENERAL SPECIFICATIONS

The Raypak water heaters are design certified by the American Gas Association, and tested under the require- ments of the American National Standard, ANSI Z21.10.3. Each heater has been constructed and pressure tested in accordance with the requirements of Section IV of the American Society of Mechanical Engi- neers Code, and factory fire tested.

The heaters are designed for indoor installation with a built-in drafthood, and a built-in sub-base for combus- tible flooring. Models are available with standing pilot, or with intermittent ignition device (I.I.D). The heaters are equipped with the following components: water circula- tion pump, pressure relief valve, manual reset high limit switch, fast response temperature sensor, 40 VA trans- former, vent thermal switch, flame roll-out switch, and redundant combination gas valve. A tankstat is supplied loose for installation in the field.

SPECIFICATIONS AND DIMENSIONS

 

 

 

 

PIPING

 

 

K

 

INPUT

 

TANK

CONNECTIONS

 

 

MODEL

RECOVERY

WATER

GAS

 

 

VENT

MBH

GPH

GAL.*

NPT.

NPT.

A

B

DIA.

WH-0090

90

90

80

1"

1/2"

11"

5-3/4

5"

WH-0135

135

132

80

1-1/4"

1/2"

18"

6-1/4

6"

WH-0195

195

192

80

1-1/4"

1/2"

18"

6-1/4

7"

*May be used with other tank size capacity.

Note: Recovery GPH based on Manufacturer's rating.

Fig.#8978.5.1

3

Page 3
Image 3
Raypak 195A, 135A, 090A manual Receiving Equipment, General Specifications, Specifications And Dimensions