Simple Serviceability
Raypak’s
Ignition control
Service diagnostic panel
MVB Control Panel
Burner on/off
Pump on/off
LED status panel
CATEGORY I* BOILERS (TYPE H)
CATEGORY I* WATER HEATERS (TYPE WH)
CATEGORY IV BOILERS & WATER HEATERS (TYPE H & WH)
MVB |
|
| Flow Rates |
|
|
|
| Pressure Drops |
|
| |||
Minimum Flow | Maximum Flow |
| 20°F |
| 30°F |
| 40°F | ||||||
Model |
|
|
| ||||||||||
GPM | P FT | T °F | GPM | P FT | T °F | GPM | P FT | GPM | P FT | GPM | P FT | ||
| |||||||||||||
504 | 25 | 1.1 | 34 | 100 | 11.3 | 8 | 42 | 2.7 | 28 | 1.4 | N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
754 | 32 | 1.7 | 40 | 100 | 13.8 | 13 | 63 | 6.0 | 42 | 2.9 | 32 | 1.7 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
1104 | 46 | 4.1 | 40 | 113 | 18.6 | 16 | 92 | 13.3 | 62 | 6.7 | 46 | 4.1 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
1504 | 63 | 8.0 | 40 | 113 | 22.2 | 22 | N/A | N/A | 84 | 13.3 | 63 | 8.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
2004 | 84 | 16.0 | 40 | 113 | 27.2 | 30 | N/A | N/A | 112 | 26.9 | 84 | 16.0 | |
|
|
|
|
|
|
|
|
|
|
| |||
MVB |
|
| Flow Rates |
|
|
| Pressure Drops |
|
|
| |||
Minimum Flow | Maximum Flow |
| 20°F |
| 30°F |
|
| ||||||
Model |
|
|
|
| |||||||||
GPM | P FT | T °F | GPM | P FT | T °F | GPM | P FT | GPM | P FT |
|
| ||
|
|
| |||||||||||
504 | 50 | 2.8 | 17 | 100 | 11.3 | 8 | N/A | N/A | 28 | 1.4 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
754 | 50 | 3.5 | 25 | 100 | 13.8 | 13 | 64 | 6.1 | 42 | 3.0 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
1104 | 60 | 6.3 | 30 | 113 | 18.6 | 16 | 90 | 12.6 | 60 | 6.3 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
1504 | 82 | 12.6 | 30 | 113 | 22.2 | 22 | N/A | N/A | 82 | 12.6 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
2004 | 109 | 25.5 | 30 | 113 | 27.2 | 29 | N/A | N/A | 109 | 25.5 |
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
MVB |
|
| Flow Rates |
|
|
|
| Pressure Drops |
|
| |||
Minimum Flow | Maximum Flow | 20°F | 30°F | 40°F | |||||||||
Model | |||||||||||||
GPM | P FT | T °F | GPM | P FT | T °F | GPM | P FT | GPM | P FT | GPM | P FT | ||
| |||||||||||||
503 | 25† | 1.1 | 35 | 100 | 11.3 | 9 | 43 | 2.8 | 29 | 1.4 | N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
753 | 33† | 1.9 | 40 | 100 | 13.8 | 13 | 65 | 6.4 | 43 | 3.1 | 33 | 1.9 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
1003 | 43‡ | 3.7 | 40 | 113 | 18.6 | 15 | 87 | 12.0 | 58 | 6.0 | 43 | 3.7 | |
1253 | 54‡ | 6.2 | 40 | 113 | 22.2 | 19 | 109 | 20.9 | 73 | 10.2 | 54 | 6.2 | |
1503 | 65‡ | 9.5 | 40 | 113 | 25.5 | 23 | N/A | N/A | 87 | 16.0 | 65 | 9.5 | |
1753 | 76‡ | 13.4 | 40 | 113 | 27.2 | 27 | N/A | N/A | 101 | 22.5 | 76 | 13.4 | |
2003 | 87‡ | 15.2 | 40 | 116 | 30.2 | 30 | N/A | N/A | 116 | 31.9 | 87 | 18.9 |
Boiler Only
*Category I with vertical vent, category III with horizontal venting and no extractor.
† Minimum flow 50GPM for WH hot water supply.
6 | ‡ Use 30° column as minimum flow for hot water supply. |
|