Raypak 504 thru 2004 Heat Exchanger Jacket Operating Controls Safeties, Gas Train Other, Boilers

Models: 503 thru 2003 504 thru 2004

1 8
Download 8 pages 61.81 Kb
Page 8
Image 8
HEAT EXCHANGER

HEAT EXCHANGER

JACKET

OPERATING CONTROLS

SAFETIES

GAS TRAIN

OTHER

 

 

MVB

 

 

 

 

 

 

 

 

 

Water Heaters

 

Boilers

 

 

 

 

(Type WH)

 

(Type H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASME, National Board Registered, 160 PSI

• HLW Stamp



 

N/A

 

 

 

• H Stamp

N/A



Heat Exchanger Tubes

 

• Copper





 

 

 

• Cupro Nickel





Bronze Headers

 

 

 





Cast Iron Headers

 

 

 

N/A



Pressure Relief Valve

 

• 60 PSI





 

 

 

• 125 PSI





 

 

 

• 30, 45, 75, 150 PSI





Temperature & Pressure Gauge

 

 





Pump

 

• 120V, Single-Phase





 

 

 

 

 

 

Indoor/Outdoor Certified

 

 





Vent Terminal

 

• Outdoor





 

 

 

Through-the-Wall





Fully-Enclosed Controls

 

 





Combustible Floor Rated

 

 





 

 

 

 

 

 

120V Power Supply with 120V/24V Transformer

 

 





On/Off Switch

 

 

 





Programmable Pump Time Delay, Single-Phase

• Included in TempTracker Mod Controller





Terminal Block Connections

• Enable / Disable





 

 

 

• External Interlocks





 

 

 

0-10 VDC Setpoint/Direct Drive Input (cat. I)





12 Diagnostic Lights with 256-Event History

 

 





Status Display Lights (4)

 

 





Temperature Controller with 3 Water Sensors

• TempTracker Mod (up to 4:1 Turndown, cat. IV)





 

 

 

• Outdoor Reset Sensor

N/A



Multiple Boiler Controller

• TempTracker Mod+, up to 16 boilers





 

 

 

Y-200, up to 40 boilers (LonWorks optional)





 

 

 

 

 

 

Hot Surface Ignition System

1-try (standard on cat. IV)





 

 

 

3-try (standard on cat. I)





High/Low Gas Pressure Switches

 

 





Blocked Vent and Air Pressure Switches

 

 





High Limit Switch

 

• Manual Reset, Fixed





 

 

 

• Manual Reset, Adjustable





 

 

 

• Automatic Reset, Adjustable





Low Water Cut-Off, 24V

• With Manual Reset and Test Buttons





Flow Switch

 

 

 





 

 

 

 

 

 

Modulating Combination Gas Valve

 

 





Combustion Air Blower

 

 





TruSeal Direct-Vent Ready

 

 





Additional Safety Valve

• Motorized (externally mounted)





 

 

 

• Solenoid (externally mounted)





 

 

 

 

 

 

CSA-Certified Efficiency

• Cat. IV - 87% at Full Fire





 

 

 

• Cat. I - 84% to 85% (see MBTUH table)





Air Filter

 

 

 





Alarm System

 

 

 





CSD-1 / GE GAP Control System

 

 





Low NOx

 

• Meets all current requirements





Cold Water Start

 

• Prevents internal condensation on start-up





Cold Water Run

 

• Prevents condensation in continuous low-temp operation 



  = Standard

  = Optional

 

 

 

 

 

Raypak, Inc. • 2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

Cat. No. 3400.11E Effective 07-01-08 Replaces 11-1-07

Page 8