RedMax BCZ2450T Troubleshooting guide, Case 1. Starting failure, Check, Probable Causes, Action

Models: BCZ2450S BCZ2450T

1 76
Download 76 pages 45.12 Kb
Page 22
Image 22
13. Troubleshooting guide

BCZ2450S/T

13. Troubleshooting guide

Case 1. Starting failure

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel

drain it and with correct fuel

fuel filter

fuel filter is clogged

clean

carburetor adjustment screw

out of normal range

adjust to normal range

sparking (no spark)

spark plug is fouled/wet

clean/dry

 

plug gap is incorrect

correct (GAP: 0.6 – 0.7 mm)

spark plug

disconnected

retighten

 

 

 

 

 

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

replace

cylinder fin, fan cover

clogged with dust

clean

When your unit seems to need further service, please consult with our service shop in your area.