RedMax HBZ2500 manual Troubleshooting guide,  14 , Check, Probable Causes, Action

Models: HBZ2500

1 22
Download 22 pages 20.69 Kb
Page 14
Image 14
Troubleshooting guide

Troubleshooting guide

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel

fuel filter

fuel filter is clogged

carburetor adjustment screw

out of normal range

sparking (no spark)

spark plug is fouled/wet

 

plug gap is incorrect

spark plug

disconnected

drain it and with correct fuel

clean

adjust to normal range

clean/dry

correct (GAP: 0.6~0.7mm)

retighten

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

wash

When your unit seems to need further service, please consult with our RedMax service shop in your area.