Redring HOW TO MAINTAIN YOUR EXPRESSIONS 500S SHOWER, What To Do If Things Go Wrong, Self Help

Models: 500S

1 13
Download 13 pages 35.21 Kb
Page 5
Image 5
HOW TO MAINTAIN YOUR EXPRESSIONS 500S SHOWER

will turn off the power to the heating elements, resulting in a cold shower.

HOW TO MAINTAIN YOUR EXPRESSIONS 500S SHOWER

This will be indicated by the middle power setting indication lights flickering and going out.

It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use of abrasive or solvent cleaning fluid be avoided.

We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally switching on the shower.

WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,

YOU MUST CLEAN THE SHOWER HANDSET REGULARLY

All water contains particles of lime, which build up in the shower handset and unit reducing the performance.

It is therefore important to clean the shower handset by simply rubbing the rubber nozzles.

NOTE: After use it is normal for some water to drip from the shower handset for a few moments. This inhibits scale build-up over prolonged use.

WHAT TO DO IF THINGS GO WRONG (1)

SELF HELP

If the shower is unsatisfactory, make the following checks before calling out the contractor. Any one of these adjustments could restore the performance.

The shower cycles

The shower temperature is set too hot causing the thermal cut-out (safety

from HOT to COLD

device) to operate.

 

Turn knob “C” clockwise (direction of the “blue arrows”) to increase water flow.

 

Slowly increase the water temperature by turning knob “C” anti-clockwise in the

 

direction of the “red arrows” until a comfortable showering temperature has

 

been reached.

 

You MUST WAIT approximately 20 seconds for each adjustment to affect the

 

water temperature.

 

“Med (medium)” setting may need to be selected.

 

 

Water too HOT

Increase water flow by adjusting knob “C” clockwise (direction of the “blue

 

arrows”).

 

“Med (medium)” setting may need to be selected.

 

Increase pressure to water supply e.g. fully open service valve or stop cock.

 

Check hose is not kinked restricting the water flow.

 

Clean shower handset.

 

 

Water too COLD

Check power is on by neon being illuminated.

 

Decrease water flow by adjusting Knob “C” anti-clockwise (direction of the “red

 

arrows”).

 

“High” setting may need to be selected.

 

Select inner or outer only handset spray pattern.

Spray pattern poor

Clean the shower handset.

 

 

Water takes longer

Thermal cut-out has operated after previous use (“Overheat” light is on)

to heat up

(automatically resets when unit cools down)

 

“High” setting may need to be selected.

 

 

Water goes cold

Check neon light is on.

while using

Check water pressure has not fallen so far as to let pressure switch cut out,

shower

e.g. Another tap drawing water off.

 

Raise position of shower handset.

 

 