Check the spray plate is then free to rotate to give the three settings.

In some winter conditions, when the incoming mains water is particularly cold it may be necessary to select the inner or outer spray pattern only. This will ensure correct operation of the shower with a slightly lower water flow rate

Note: After use it is normal for some water to drip from the showerhead for a few moments, this inhibits scale build up over prolonged use.

What to do if things go wrong

SELF HELP

If the shower is unsatisfactory, make the following checks before calling out the contractor. Any of these adjustments could restore the performance

 

Increase water flow by adjusting the

a) Water too HOT

temperature control clockwise.

 

Clean spray plate holes. (Select outer or

 

combination spray patterns).

 

Switch power to MEDIUM setting.

 

Increase pressure of water supply e.g. fully

 

open service valve or stop cock. Check hose is

 

not kinked restricting the water flow.

 

Decrease water flow by adjusting the

b) Water too COLD

temperature control anti-clockwise.

 

Select inner or outer spray patterns only.

 

Switch power to HIGH setting.

c) Spray pattern poor

Clean spray plate and flush heater. (Select

inner / outer spray pattern).

 

 

Check water pressure has not fallen so far as

d) Water goes cold while using shower

to let pressure switch cut out, e.g. another tap

 

drawing water off.

 

Raise position of handset.

 

Please contact our spares department on

e) Broken parts

0870 0102 829.

 

Fitting instructions are provided with spares.

 

 

PROFESSIONAL SERVICE

 

If the previous checks fail to restore the performance, you should either contact the Redring Technical Advisory Service or seek the assistance of a qualified plumber and / or electrician.

The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have a problem in the guarantee period.

The following additional checklist is provided for the benefit of the qualified serviceman.

WARNING – SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE REMOVING THE COVER TO MAKE CHECKS.

5

Page 5
Image 5
Redring 600, 620 manual What to do if things go wrong