| Water too cold – Neon light on |
|
| |||
Temperature dial |
| Turn the temperature dial located on the bottom of the water heater clockwise for | |||||
is turned too low |
| hotter temperatures. Refer to Graph 1 for outlet temperature vs. flow rate variance. | |||||
|
|
|
|
|
|
| |
Water flow is too |
| Adjust water flow to stay within the water heater’s specifications. See Graph 1 on | |||||
high |
| Page 8 of this manual. |
|
|
| ||
|
|
|
|
|
|
| |
One or more of the |
| Shut off the power to the unit, remove the cover and locate therm al cutouts on the | |||||
heating module |
| top of each heating module. Try resetting each cutout by pushing the reset button | |||||
thermal |
| located in the center of the cutout. Determine and fix the cause of the overheating. | |||||
has tripped |
| Obstructions in the water path can restrict the flow of water through the heater | |||||
|
| causing it to overheat. Verify the heater’s inlet filter screen and all outlets served | |||||
|
| by the heater are clear of debris. Ensure the heater is not being fed preheated | |||||
|
| water. This water heater is designed for a cold water feed only. If thermal cut out | |||||
|
| does not reset, check for continuity through each cutout (Less than 0.5 Ohms). If | |||||
|
| any cutout reads more than 0.5 Ohms or open, then it may be defective and | |||||
|
| should be replaced. |
|
|
|
| |
|
|
| |||||
The power supply |
| This is likely an issue with the incoming power supply. Have a qualified electrician | |||||
voltage has |
| measure voltage on the water heater’s terminal block while operating at maximum | |||||
dropped |
| flow and maximum temperature setting. The AE115 / AE125 models are rated for | |||||
|
| 240V and will also operate at 220V or 208V with reduced output. The output will | |||||
|
| vary in accordance with the following ratios: |
|
| |||
|
|
|
|
|
|
|
|
|
| Volts |
| 208 | 220 | 240 |
|
|
| Output Ratio |
| 0.75 | 0.84 | 1.0 |
|
|
|
| |||||
The inlet water |
| Verify the heater is sized appropriately for it’s geographic location. Turn | |||||
temperature is too |
| temperature knob located on the bottom of the water all the way clockwise for | |||||
cold |
| maximum temperature setting. Ensure flow rates are within the heater’s | |||||
|
| specifications. Refer to Graph 1 on Page 8 of the manual. Use of an isolation | |||||
|
| valve on the hot water outlet to control flow rate is recommended. | |||||
|
|
| |||||
One of the power |
| Have a licensed electrician verify adequate voltage on the terminal block inside | |||||
supplies is not on |
| the water heater. Verify circuit breakers serving the heater are not tripped. See | |||||
|
| the “Electrical connections” section on Page 5 of this manual. | |||||
|
|
| |||||
Premature element |
| Shut off power to the unit and remove cover. Use an ohmmeter to verify correct | |||||
failure |
| resistance on each element. If readings are different than listed specifications on | |||||
|
| Page 14, contact Technical Support (866) | |||||
|
|
|
|
|
|
|
|
13