Water too cold – Neon light on

 

 

Water too cold – Neon light on

 

 

Temperature dial

 

Turn the temperature dial located on the bottom of the water heater clockwise for

is turned too low

 

hotter temperatures. Refer to Graph 1 for outlet temperature vs. flow rate variance.

 

 

 

 

 

 

 

Water flow is too

 

Adjust water flow to stay within the water heater’s specifications. See Graph 1 on

high

 

Page 8 of this manual.

 

 

 

 

 

 

 

 

 

 

One or more of the

 

Shut off the power to the unit, remove the cover and locate therm al cutouts on the

heating module

 

top of each heating module. Try resetting each cutout by pushing the reset button

thermal cut-outs

 

located in the center of the cutout. Determine and fix the cause of the overheating.

has tripped

 

Obstructions in the water path can restrict the flow of water through the heater

 

 

causing it to overheat. Verify the heater’s inlet filter screen and all outlets served

 

 

by the heater are clear of debris. Ensure the heater is not being fed preheated

 

 

water. This water heater is designed for a cold water feed only. If thermal cut out

 

 

does not reset, check for continuity through each cutout (Less than 0.5 Ohms). If

 

 

any cutout reads more than 0.5 Ohms or open, then it may be defective and

 

 

should be replaced.

 

 

 

 

 

 

 

The power supply

 

This is likely an issue with the incoming power supply. Have a qualified electrician

voltage has

 

measure voltage on the water heater’s terminal block while operating at maximum

dropped

 

flow and maximum temperature setting. The AE115 / AE125 models are rated for

 

 

240V and will also operate at 220V or 208V with reduced output. The output will

 

 

vary in accordance with the following ratios:

 

 

 

 

 

 

 

 

 

 

 

 

Volts

 

208

220

240

 

 

 

Output Ratio

 

0.75

0.84

1.0

 

 

 

 

The inlet water

 

Verify the heater is sized appropriately for it’s geographic location. Turn

temperature is too

 

temperature knob located on the bottom of the water all the way clockwise for

cold

 

maximum temperature setting. Ensure flow rates are within the heater’s

 

 

specifications. Refer to Graph 1 on Page 8 of the manual. Use of an isolation

 

 

valve on the hot water outlet to control flow rate is recommended.

 

 

 

One of the power

 

Have a licensed electrician verify adequate voltage on the terminal block inside

supplies is not on

 

the water heater. Verify circuit breakers serving the heater are not tripped. See

 

 

the “Electrical connections” section on Page 5 of this manual.

 

 

 

Premature element

 

Shut off power to the unit and remove cover. Use an ohmmeter to verify correct

failure

 

resistance on each element. If readings are different than listed specifications on

 

 

Page 14, contact Technical Support (866) 330-2729 for further instruction.

 

 

 

 

 

 

 

 