Redring AE115, AE125 manual Installing the PowerStar, Specifications, Disclaimer

Models: AE125 AE115

1 16
Download 16 pages 28.12 Kb
Page 3
Image 3
Specifications

Specifications

 

AE115 Unit

AE125 Unit

Voltage supply

2 x 240V AC (Canada 240VAC)

3 x 240V AC (Canada 240VAC)

Amperage

2 x 40 A (Canada 80 A)

3 x 40 A (Canada 120 A)

Maximum output

17.25 kW

26.85kW

Temperature control range

95°F to 131°F

95°F to 131°F

Pressure range

15 psi to 150 psi

15 psi to 150 psi

Minimum flow rate

0.6 US gal / min

0.8 US gal / min

Maximum flow rate

See Graph 1, Page 8

See Graph 1, Page 8

Dimensions (excl. water couplers)

15½” H x 151/4” W x 4½” D

15½” H x 151/4” W x 4½” D

Weight (without water)

20 lbs

22 lbs

Note: The unit will work at lower supply voltages but the following changes will apply:

Maximum output

15kW at 220V

22.5kW at 220V

 

13kW at 208V

20kW at 208V

Temperature control range

87°F to 116°F at 220V

87°F to 116°F at 220V

 

82°F to 108°F at 208V

82°F to 108°F at 208V

Maximum flow rate

84% of maximum at 220V

84% of maximum at 220V

(refer to Graph 1, Page 8)

75% of maximum at 208V

75% of maximum at 208V

Installing the PowerStar

WARNING:

If water supply has a high mineral content, a water softening system is strongly recommended. Damage to the water heater resulting from scale or hard minerals will not be covered under warranty.

DISCLAIMER:

In the Commonwealth of Massachusetts a licensed plumber or electrician must perform the installation. (Approval number: P1-09-25).

Locating the Powerstar

WARNING:

Do not install the water heater in an area where there is a chance of freezing. Damage to the water heater as a result of freezing will not be covered under warranty.

If being used in a public place, locate the heater out of easy reach to discourage vandalism.

Mount the unit onto a flat section of wall, well away from any potential splashes of water or spray and away from areas where direct moist or wet contact could occur.

Should it be necessary to service the Powerstar, observe the following clearances. These are not required clearances, but would facilitate any service work.

Recommended minimum clearances for servicing

Top

12”

Bottom

6”

Sides

0”

Front

12”

3