PROBLEM

SOLUTION

 

 

4. The walking belt is

a. If the walking belt is off-center, first re-

a

 

off-center or slips

move the key and UNPLUG THE POWER

 

 

 

when walked on

CORD. If the walking belt has shifted to

 

 

 

the left, use the allen wrench to turn the

 

 

 

left rear roller bolt clockwise 1/2 of a turn; if

 

 

 

the walking belt has shifted to the right,

 

 

 

turn the left rear roller bolt counterclock-

 

 

 

wise 1/2 of a turn. Be careful not to over-

 

 

 

tighten the walking belt. Plug in the power

 

 

 

cord, insert the key and run the treadmill for

 

 

 

a few minutes. Repeat until the walking belt is centered.

 

 

b. If the walking belt slips when walked on,

b

 

 

first remove the key and UNPLUG THE

 

 

 

 

 

POWER CORD. Using the allen wrench,

 

 

 

turn both rear roller bolts clockwise 1/4 of a

 

 

 

turn. When the walking belt is correctly

 

 

 

tightened, you should be able to lift each

 

 

 

side of the walking belt 3 to 4 inches off the

 

 

 

walking platform. Be careful to keep the

 

 

 

walking belt centered. Plug in the power

 

 

 

cord, insert the key, and walk on the tread-

 

 

 

mill for a few minutes. Repeat until the walking belt is properly tightened.

 

5. The displays of the

a. Remove the key from the console and UN-

a

 

console do not func-

PLUG THE POWER CORD. Next, remove

 

1/8”

 

tion properly

the screws from the hood and carefully re-

 

99

11

 

move the hood. Locate the Reed Switch

 

 

 

 

12

 

(17) and the Magnet (12) on the left side of

17

 

the Pulley (11). Turn the Pulley until the

Top

 

 

Magnet is aligned with the Reed Switch.

 

 

Make sure that the gap between the

View

 

 

Magnet and the Reed Switch is about

 

 

 

1/8”. If necessary, loosen the Reed Switch

 

 

 

Screw (99) and move the Reed Switch slightly. Retighten the Screw. Re-attach the

 

hood and run the treadmill for a few minutes to check for a correct speed reading.

6.The chest pulse sen- sor does not function properly

a. If the chest pulse sensor does not function properly, refer to CHEST PULSE SENSOR TROUBLESHOOT- ING on page 7.

b. If the chest pulse sensor still does not function prop- erly, the battery should be changed. To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover and turn the cover counterclockwise to the “open” position. Remove the cover.

Next, remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the bat- tery cover and turn it to the closed position.