Gas Fireplaces

Vertical termination with co-linear flex system

The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.

Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

This appliance is designed to be attached to two 3” (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements for minimum and maximum heights.

Co-linear DV

 

Vertical Termination

 

Cap # 946-529

 

A maximum

 

of two certified

 

joiner kits

 

may be used

 

per length.

Flex Liner

#948-305

 

35 ft (11m)

 

Exhaust

 

Flue

 

Outer

 

Pipe

 

with Kit#

 

946-563

 

 

Air Intake

Pipe Length

 

 

Co-Linea

Rigid Pipe Adapter

Flex

Adapter

# 510-994

with Kit#

 

 

946-563

45o Elbow

Inner Pipe

Adapter with Kit# 946-563

P33 Gas Fireplace

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical Termination Cap

948-305

3” Flex - 35 ft.

946-563

Coaxial to Co-linear Adapter Kit

510-994

Rigid Pipe Adapter

58dva-E45

45º Elbow

Alternate Approved Caps

46dva-VC

Vertical Termination Cap

46dva-VCH

High Wind Cap

 

 

46dva-GK

3” Co-linear Adapter with flashing

30

VerticalHeight(feet)

(51mm)max.

8'(2.4m)Min.

30'(9.1m)Max.

 

2’

 

 

 

 

30”

(762mm)

Horizontal Distance (Feet)

The shaded area in the diagrams show the allowable vertical

terminations.

Gas Fireplaces

Please refer to Exterior Vent Terminations for

additional guidelines on vent locations.

August 2008 Product Specifications Book