Gas Fireplaces

P33 Gas Fireplace

Horizontal Venting with Two (2) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H+ H1

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

1’ Min.

3’ Max.

30 feet.

 

 

 

B)

2’ Min.

4’ Max.

Total horizontal sections must

 

 

 

not exceed 8 feet.

C)

3’ Min.

5’ Max.

Minimum of 1 foot between

 

 

 

D)

4’ Min.

6’ Max.

90° elbows is required.

E)

5’ Min.

7’ Max.

 

 

 

 

 

F)

6’ Min.

8’ Max.

 

Horizontal Venting with Two (2) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

1’ Max.

1’ Min.

3’ Max.

30 feet.

 

 

 

 

B)

2’ Max.

2’ Min.

5’ Max.

Total horizontal sections must

 

 

 

 

not exceed 8 feet.

C)

3’ Max.

4’ Min.

6’ Max.

Minimum of 1 foot between

 

 

 

 

D)

4’ Max.

6’ Min.

7’ Max.

90° elbows is required.

 

 

 

 

 

E)

5’ Max.

8’ Min.

8’ Max.

 

 

 

 

 

 

36

Gas Fireplaces

Horizontal Venting with Three (3) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

H + H1

Maximum total

 

 

 

 

 

pipe: length, of

A)

2’ Min.

1’ Max.

3’ Min.

4’ Max.

all sections, must

 

 

 

 

 

B)

3’ Min.

2’ Max.

4’ Min.

5’ Max.

not exceed 30

 

 

 

 

 

feet.

C)

4’ Min.

3’ Max.

6’ Min.

6’ Max.

Total horizontal

 

 

 

 

 

D)

5’ Min.

4’ Max.

8’ Min.

7’ Max.

sections must not

 

 

 

 

 

exceed 8 feet.

E)

6’ Min.

5’ Max.

10’ Min.

8’ Max.

Minimum of 1

F)

7’ Min.

6’ Max.

12’ Min.

9’ Max.

foot between

90° elbows is

 

 

 

 

 

 

 

 

 

 

required.

Horizontal Venting with Three (3) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1 + H2

Maximum total pipe:

 

 

 

 

length, of all sections,

A)

1’ Max.

1’ Min.

3’ Max.

must not exceed 30

 

 

 

 

feet.

B)

2’ Max.

3’ Min.

5’ Max.

Total horizontal sections

 

 

 

 

must not exceed 7

C)

3’ Max.

5’ Min.

6’ Max.

feet.

 

 

 

 

 

 

 

 

Minimum of 1 foot

D)

4’ Max.

7’ Min.

7’ Max.

between 90° elbows

 

 

 

 

 

 

 

 

is required.

E)

5’ Max.

9’ Min.

8’ Max.

 

 

 

 

 

 

F)

6’ Max.

11’ Min.

9’ Max.

 

 

 

 

 

 

August 2008 Product Specifications Book

Page 9
Image 9
Regency 946-523/P, 510-994 specifications Minimum, Foot between, Elbows is, Required, Option + H1 + H2