INSTALLATION
MOBILE HOME INSTALLATION
Once you have properly marked the position of your unit and the floor protec- tion as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole through your outside wall. Use 4" duct pipe with a mesh grill to pipe fresh air into the back shield area. Place your unit in position and secure it to the floor using two lag bolts 3/8" x
For Mobile Home units installed in the U.S; the unit must be grounded using a #8 ground wire with approved termination and star washer.
WARNING:
Minimum height requirements must be met. Safe removal of the chimney system must be adhered to when transporting the mobile home.
WARNING: Operate only with door fully closed - open feed door to feed fire only.
4" outside air kit
Secured to floor with 2 lag bolts.
Regency CS1200 Freestanding Wood Stove