Regency CS1200 Installation, Minimum Clearance To Combustible Materials, F D C F C

Models: CS1200

1 32
Download 32 pages 18.97 Kb
Page 7
Image 7
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

INSTALLATION FROM THE REAR HEAT SHIELD TO A BACK WALL

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND

FROM THE REAR HEAT SHIELD TO A BACK WALL

B

E

A

 

F

D FCheck with your local inspector.

C

F

C

NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.

Check with your local inspector.

Residential Installation “C” Vent (Single Wall)

Unit

 

From Unit

 

From Corner

From Flue Center-line

 

 

 

 

 

 

 

 

 

CS1200

A

 

B

C

 

D

E

F

 

 

 

 

 

 

 

 

13"

 

11"

8"

 

26-3/8"

18-1/2"

20-3/4"

 

 

 

 

 

 

 

 

 

 

 

 

Residential Close Clearance (To be installed with required pipe components)

When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.

 

 

From Unit

 

From Corner

From Flue Center-line

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

E

F

CS1200

 

 

 

 

 

 

 

 

11"

 

7"

7"

 

24-1/2"

14.5"

19-3/4"

 

 

 

 

 

 

 

 

 

 

 

 

Mobile Home Close Clearance (To be installed with required pipe components)

"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)

 

 

From Unit

 

From Corner

From Flue Center-line

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

E

F

CS1200

 

 

 

 

 

 

 

 

11"

 

7"

7"

 

24-1/2"

14.5"

19-3/4"

 

 

 

 

 

 

 

 

 

 

 

 

Regency CS1200 Freestanding Wood Stove

7 CS1200

Page 7
Image 7
Regency CS1200 Installation, Minimum Clearance To Combustible Materials, F D C F C, Check with your local inspector