MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS

CanadaINSTALLATION

MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS

MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND

FROM THE REAR HEAT SHIELD TO A BACK WALL

The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height - 84"

Maximum depth of alcove - 36"

Minimum Alcove Clearance to Combustible Materials

Unit

From Back Shield

 

From Flue

Min.

Min. Hearth

 

+ Side Shields.

Center-Line

Width

to Rear Wall

 

 

 

 

 

 

 

 

CS1200

G

H

I

 

J

K

L

 

 

 

 

 

 

 

11"

7"

24-1/2"

 

14-1/2"

49-1/8"

39-1/4"

 

 

 

 

 

 

 

 

 

 

Floor Protection

A combustible floor must be protected by a non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extend- ing beneath the heater and a minimum of 6" from each side and minimum 16" from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove.

Minimum Overall Width (X) of Floor

Protector for all installations:

US

38-3/4"

6"

 

Canada

42-3/4"

 

 

 

 

 

 

6"

 

Z

6"

6"

 

16"

 

X

Y X

6"

16"

Z

Y Manual background6"

for angled corners

NOTE: In Canada, floor protection must extend 18" to the front and 8" to each side of the stove.

Minimum Overall Depth (Y) of Floor Protector

Unit

Residential

Residential

Mobile Home

 

Alcove

 

"C" Vent

Close Clearance

Close Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1200

Y

Z

Y

Z

Y

Z

Y

 

Z

 

 

 

 

 

 

 

 

 

 

USA

39"

6"

39

6"

39"

6"

39"

 

6"

 

 

 

 

 

 

 

 

 

 

Canada

43"

8"

43"

8"

43"

8"

43"

 

8"

 

 

 

 

 

 

 

 

 

 

8