Blower/Fan (846-515)
1) Remove the two screws from the top of the
fan housing.
2) Slide the fan up into the rear heat shield.
3) After aligning holes, secure the fan to the rear
heat shield using the two screws removed
earlier.
Note: The connection cord should not be
in contact with any hot surfaces.
Read the operating instructions for the fan
before using.
INSTALLATION

Ground

Fan Fan

Ground Green
Neutral
Live
White
Fan
Switch
Manual/
Auto
Switch
Black Black
High(Black)
Low(Red)
Black
FanThermodisc
(normallyopen)
120VAC
60Hz
Blower/Fan Wiring Diagram
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged

(grounding) plug for your protection against shock

hazard and should be plugged directly into a properly

grounded three-prong receptacle. Do not cut or remove

the grounding prong from this plug.

NOTE: This appliance, when installed, must
be electrically grounded in accordance
with local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
code, CSA C22.1.