Regency E21, U20 Gas Supply Line, Electrical Supply, Installation, Specifications

Models: E21 U20

1 12
Download 12 pages 58.44 Kb
Page 9
Image 9
GAS SUPPLY LINE

INSTALLATION

OPTIONAL OUTSIDE COMBUSTION AIR SUPPLY INSTALLATION

A 4" (100 mm) dia. aluminum flex pipe or equivalent may be installed from the outside (with a proper exterior cover) to the Zero Clearance cabinet. There is an outside hole provided on the rear wall of the kit. This will provide adequate outside combustion air supply to the heater.

GAS SUPPLY LINE

An authorized service person should install the gas line in accordance with all local building codes. If codes permit, flex gas line or coiled copper tubing may be used as gas supply line. The suggested way to install the gas supply line is as follows: run 1/2" (9.5 mm) NPT gas line to the left side of the framed opening. (See U20/E21 installation instructions for additional information).

Specifications

 

Min. Inlet

Input

 

Gas Pressure

Rating

 

 

 

 

Natural Gas

4.5" w.c.

21,000

Btu/hr

 

1.12 kP

22

mj/h

 

 

 

 

Propane

11" w.c.

21,000

Btu/hr

 

2.74 kPa

22

mj/h

 

 

 

 

ELECTRICAL SUPPLY

Provide 120 VAC, 60 Hz (in Australia and New Zealand: 240 VAC, 50 Hz) receptacle within 24"(610mm) of the left side of the appliance (not inside the Zero Clearance Cabinet). Plug the cord on the appliance into the receptacle.

U20/E21 Gas Insert Zero Clearance Kit

9

Page 9
Image 9
Regency E21, U20 installation manual Gas Supply Line, Electrical Supply, Installation, Specifications