RESIDENTIAL AND MANUFACTURED HOMES /

INSTALLATION

RESIDENTIAL AND MANUFACTURED HOMES /

MOBILE HOMES INSTALLATIONS

You will require the following components with your new Regency® Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.

Note: These are the minimum pieces required.

Other parts may be required for your particular installation.

Minimum components for a Horizontal Installation:

640-944 Horizontal Termination Kit which includes:

16-5/8" Dia. x 18" Black Pipe

14" Dia. x 18" Aluminum Vent

1640-530/P Riser Vent Terminal

1946-202 Wall Penetration Heat Shield (Wall Thimble) (2 pcs)

1640-545/P Decorative Wall Trim (Black)

1948-128 Tube Mill-Pac

 

Screws

Optional Components:

946-204

45o Elbow - 6-5/8" Black pipe and 4"

 

Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

 

Terminal

946-208/P

Vent Guard

940

Square Wall Thimble Cover*

981Snorkel Termination (36")*

982Snorkel Termination (14")*

942

Wall Penetration

 

Heat Shield*

* Simpson Dura-Vent components

Alternate Snorkel

Termination Cap

Part # 982 (14")

Part # 981 (36")

HORIZONTAL TERMINATIONS

1)Set the unit in its desired location. Check to determine if wall studs are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.

2)Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down. Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape. Kit comes complete with 18" of straight vent - 6-5/8" dia. black outer pipe and 4" dia. inner vent.

3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 9-1/2"(insidedimensions)round hole.The center of the round hole should line up with the centerline of the horizontal pipe, as shown in diagram 1. Cut and frame the 9-1/2 round hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of non-combusti- ble material, i.e. masonry block or concrete, a 7" diameter hole is acceptable.

Diagram 1

Note:

a)The horizontal run of vent should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re.

b)The location of the horizontal vent ter- mination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see diagram in "Exterior Vent Terminal Locations" section.

c)Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations as shown in Dia. 2 are available, as well as the standard Riser Vent. Follow the same installation procedures as used for standard Horizontal Termina- tion. NEVER install the snorkel upside down.

Diagram 2a

*Dia 2a & 2b: As specifi ed in CGA B149 Instal- lation Code. Local codes or regulations may require different clearances.