Regency U37-LP1 Dc Sparker Battery Replacement, Note Use a magnetic type screwdriver if possible

Models: U37-LP1 U37-NG1

1 36
Download 36 pages 55.81 Kb
Page 30
Image 30
Note: Use a magnetic type screwdriver if possible.

MAINTENANCE

4)Remove the screw that holds the DC spark generator wires in place on the valve.

5)Disconnect the DC spark generator wires from the valve.

7) At this point you should disconnect the gas at the valve. You can access it through the front now that the control panel is off, or you canaccessitthroughthe rearpedestal cover plate.

8)Carefully remove the logs and embers.

9)Remove burner. See diagram below.

Note: Use a magnetic type screwdriver if possible.

DC SPARKER

BATTERY

REPLACEMENT

The battery in the DC Spark box needs to be replaced annually.

1)Remove the DC Spark box from the back of the pedestal cover by removing the heat shield.

10) Remove all 18 screws holding the burner

2) Remove the Heat Shield from the DC

tray assembly in place.

Spark Box.

 

6) Remove the two outside frame pieces by removing two screws per side. See diagram below.

11)Carefully lift the burner tray assembly out. Be careful not to tear gaskets when lifting out the valve tray; these gaskets seal the valve from the exterior of the fi rebox.

12)To replace the burner tray assembly, simply reverse these instructions.

3)Place 1 AA battery into the DC Spark Box by opening the battery compartment.

4)Reverse steps to put back in place.

30

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Page 30
Image 30
Regency U37-LP1, U37-NG1 Dc Sparker Battery Replacement, Note Use a magnetic type screwdriver if possible