USER INSTRUCTIONS i500

Thank you for purchasing the Reliable™ i500 series iron system. Please follow the instructions carefully. With proper care and maintenance, your steamer will provide years of dependable service.

1.Remove the ironing station from its packing and make sure all packing parts have been taken off (including the protection bags). Lay the station on a flat and steady surface fitted to support it next to a wall socket (max. mt. 1,5).

2.It is recommended to lay the iron on the supplied pad.

3.Insert in the right seat (2) the small supplied wand to hold the hose up and hook it with the spring up to the iron-boiler connecting wire.

4.Unscrew the safety cap (1) and let the internal air out. Fill the boiler with: Max. 2,0 litres of water for model i500

Use the funnel supplied, making sure you do not overfill the tank.

5.Insert the plug into the main supply point; switch on boiler (4) and iron button (3). If the two buttons come on, iron and boiler are working.

6.Turn the iron plate’s temperature regulating knob (6) to the position “cotton °°°” (indicated on the iron knob).

7.Wait that the boiler button’s red light (4) goes off (it takes about 10 minutes). While ironing, the boiler button’s red light normally comes on.

8.The machine is ready for use.

9.Push the steam button (7).

10.It is possible to regulate the quantity of steam by the steam knob (8).

11.In case the steam stops during ironing and the water button’s red light

(5) comes on, it means that there is not enough water in the tank. To start ironing again, switch off the boiler button (4); press the steam iron button (7) to ensure there is no more steam in the boiler, slowly open the pressure cap (1) and refill to the required level with warm water. Replace the cap and wait for it to build up pressure again.

12.When you first press the steam button (after having turned the boiler on and depressed the steam button on the iron) you might notice a decrease in pressure. This is because the tank has air in it. In order to have plenty of steam (after you have depressed the iron) wait until the pressure goes back up to the maximum level before you begin.

IMPORTANT

When you are finished using the boiler for the day, unscrew the fill cap one- turn on the unit to release the steam/air from the tank. This will eliminate the vacuum that may cause damage to the pressure gauge.

Page 2
Image 2
Reliable I500A, i500B instruction manual

i500, I500A, i500B specifications

The Reliable i500B, i500A, and i500 are a series of high-performance commercial steam boilers that stand out in the industry for their innovative design, efficiency, and reliability. These models are tailored for users who require robust solutions for various steam needs, from industrial applications to food processing and cleaning operations.

The i500B model is known for its powerful output, designed to handle high-demand scenarios. With a high efficiency that reaches up to 90%, the i500B offers optimal fuel consumption while providing superior steam quality. Its advanced burner technology ensures a clean burn, reducing emissions and operational costs. Additionally, the unit features an intelligent control system that simplifies operation, allowing users to optimize performance and maintain precise steam temperature and pressure.

Moving to the i500A, this model is particularly recognized for its compact design without compromising on performance. It is ideal for smaller spaces or applications where footprint is a concern. The i500A boasts features such as a high-capacity feed water system and robust insulation, resulting in reduced heat loss and improved efficiency. This model also integrates a user-friendly control panel that facilitates real-time monitoring and adjustments, making it easier for operators to manage the steam supply.

Lastly, the base i500 model holds its ground as a versatile choice for a variety of applications. It combines reliability with an economical approach to steam generation. The i500 is engineered with durable materials and corrosion-resistant components, ensuring a long service life with minimal maintenance. Its integrated safety features and automatic shut-off systems enhance operational reliability, making it a preferred option for facilities that prioritize safety.

All three models utilize state-of-the-art technologies such as modulating burners, advanced heat recovery systems, and comprehensive diagnostic capabilities. These features contribute to their ability to adapt to fluctuating steam demands efficiently, ensuring consistent performance.

In summary, the Reliable i500B, i500A, and i500 series represent some of the best options available for efficient and reliable steam generation. Their advanced technologies and thoughtful design cater to a wide range of industrial needs, ensuring that users benefit from both performance and economy. Whether in a large manufacturing plant or a smaller workshop, these models provide effective steam solutions that stand the test of time.