Reliance Water Heaters 184123-000 Installation Checklist, Installing the New Water Heater cont’d

Models: 184123-000

1 24
Download 24 pages 25.35 Kb
Page 15
Image 15
Installation Checklist

Installing the New Water Heater (cont’d)

Installation Checklist

BEFORE LIGHTING THE PILOT:

1.Check the gas lines for leaks.

a.Use a soapy water solution. DO NOT test for gas leaks using a match or open flame.

b.Brush the soapy water solution on all gas pipes, joints and fittings.

c.Check for bubbling soap. This means you have a leak. Turn “OFF” gas and make the necessary repairs.

d.Recheck for leaks.

e.Rinse off soapy solution and wipe dry.

2.Is the new temperature-pressure relief valve prop- erly installed and piped to an adequate drain? See “Temperature-Pressure Relief Valve” section.

3.Are the cold and hot water lines connected to the water heater correctly? See “Water Piping” instruc- tions in the “Installing the New Water Heater” section.

4.Is the water heater completely filled with water? See “Filling the Water Heater” instructions in the “Installing the New Water Heater” section.

5.Will a water leak damage anything? See the “Locating the New Water Heater” section.

6 . Is there proper clearance between the water heater and anything that might catch fire? See the “Locating the New Water Heater” section.

7 . Do you have adequate ventilation so that the water heater will operate properly? See the “Locating the New Water Heater” section.

8 . Is the draft hood vent piping properly secured? See “Venting” instructions in the “Installing the New Water Heater” section.

9.Is there proper clearance between the vent pipe and anything that might catch on fire? See “Venting” instructions in the “Installing the New Water Heater” section.

10.Is the vent pipe properly sloped and does the vent terminate outdoors? See “Venting” instructions in the “Installing the New Water Heater” section.

11.Do you need to call your gas company to check the gas pipe and its hookup?

VENT PIPE TO UL

LISTED ROOF JACK

HOT

TEMPERATURE-PRESSURE

RELIEF VALVE

GAS SUPPLY

SHUTOFF VALVE

COLD

TEE

SHUTOFF

DRIP LEGVALVE (Sediment trap)

 

 

 

 

DRAIN VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIPE CAP

 

 

 

 

DISCHARGE PIPE

 

 

 

 

 

 

 

 

 

(Do not cap or plug.

 

 

 

 

 

Must terminate beneath

 

 

 

 

 

manufactured home.)

MODEL RATING PLATE

SUITABLE FOR WATER (POTABLE)

HEATING ONLY

AUTOMATIC STORAGE WATER HEATER FOR INSTALLATION IN A MANUFACTURED HOME

*ORIFICE SIZE: #40 FOR NAT. / #52 FOR LP

IF CONVERTED - PROPANE RATE: 30,000 BTU

*For 30 and 40 Gal. heater as shown

For 50 Gal. heater:

ORIFICE SIZE: #35 FOR NAT. / #51 FOR LP

IF CONVERTED - PROPANE RATE: 38,000 BTU