Reliance Water Heaters 184123-000 instruction manual “Fuel” Conversion Instructions

Models: 184123-000

1 24
Download 24 pages 25.35 Kb
Page 13
Image 13
“Fuel” Conversion Instructions

Installing the New Water Heater (cont’d)

“Fuel” Conversion Instructions

From Natural Gas To Propane

(L.P.) Gas

Read and follow detailed conversion instructions below and also in the instruction manual in their entirety before starting the conversion.

Conversion kit with necessary parts are in a bag attached to the drain valve.

Step 1. Turn gas control knob “A” to “PILOT”. Depress and turn “OFF”. (See Figure 4, page 14).

Step 2. Remove outer and inner access doors from water heater.

Step 3. Remove burner assembly from water heater and con- trol by loosening 34nut “H” holding burner assem- bly to control. (See Figure 5, page 14). Loosen pilot tube nut “J” and thermocouple nut “K” at control.

Step 4. Remove screws “D” disengaging manifold from burner. (See Figure 6, page 14)

Step 5. Remove orifice “E” (See Figure 6, page 14) using 38wrench. Install orifice marked “L.P.” found in the bag into manifold. Tighten securely. Secure burner to manifold with screws “D”.

Step 6. Loosen pilot tube nut “F” (See Figure 7, page 14). Remove orifice “G” and replace with red colored orifice found in bag. Reinstall nut “F” and tighten securely.

Step 7. Make sure all connections are tightened securely, and reinstall burner assembly into water heater. Po- sition end of the manifold inside bracket as shown in Figure 6 on page 14. Reinstall manifold into control and tighten 34 inch nut (“H”) securely. Recheck to see that end of manifold is still inside bracket as shown in Figure 6 on page 14. Reinstall pilot tubing and thermocouple into control. (See Figure 5, page 14)

Step 8. Place screwdriver in slot “B”. (See Figure 4, page

14). Depress and turn counter-clockwise (From Natural Gas To Propane ) to stop. Control screw must be in “IN” position for propane (L.P.) gas and in “OUT” position for natural gas. STOP! Read label “For Your Safety” located on your water heater.

Step 9. Set the thermostat to lowest setting by turning the

water temperature dial clockwise, (Manual background ) to its lowest temperature setting (with arrow on dial) as shown.

Step 10. Turn gas control knob clockwise to “OFF” position. Knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.

Step 11. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety in- formation on “For Your Safety” label. If you don’t smell gas, go to the next step.

Step 12. Find pilot-follow metal tube from gas control. The pilot is located in front of the burner. (See Figure 7, page 14)

PILOT BURNER

THERMOCOUPLE

Step 13. If you don’t smell gas, turn knob on gas control

counter-clockwise Manual background to “PILOT” position.

Step 14. Push in control knob all the way and hold down. Immediately light the pilot with a match. Continue to hold control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, re- peat steps 9 through 12.

If knob does not pop up when released, stop and immediately call the local gas supplier.

If the pilot will not stay lit after several tries, depress and turn the gas control knob clock-

wiseManual backgroundto “OFF”and call the gas supplier.

Step 15. Check for gas leaks with only pilot flame burning using a soapy water solution, not a match or open flame. Check for gas leaks at fittings “F”and “G” (See Figure 7, page 14) and at fitting “J” (See Figure 5, page 14).

Step 16. Make sure temperature adjustment dial is turned

clockwise ( Manual background) in its lowest position (See Figure 4, page 14).

Step 17. Replace inner and outer doors.

Step 18. At arms length away turn gas control knob to the full “ON” position. WARNING: Do not use gas control knob to regulate gas flow. Turn tempera-

ture adjustment dial counter-clockwise ( Manual background ) until gas flows to main burner and ignites.

Step 19. With a soapy water solution, not a match or open flame, check for gas leaks at gas connection “H”. (See Figure 5, page 14). If gas leak occurs, turn off immediately by shutting off gas cock at inlet to

control,or by turning gas control knob Manual background to “PILOT” pushing down and turning to “OFF”. Re- pair gas leak as necessary, and repeat steps 9 through 19.

Step 20. At arm’s length away, set the thermostat to desired setting. The mark (▼) HOT indicative of approx. 120°F is preferred starting point. Some local laws may require a lower starting point. If hotter water is desired see the Temperature Regulation” sec- tion in this manual.

13

Page 13
Image 13
Reliance Water Heaters 184123-000 instruction manual “Fuel” Conversion Instructions, From Natural Gas To Propane L.P. Gas