Explanation of Prompting and

Error Messages

Display

Prompt or Error

HI

Indicates arc voltage is above 80V DC.

---Indicates selected Run-In speed will be the same as the weld speed. To enter a different Run-In speed simply press the increase arrow key with Run-In selected.

HXX

Indicates wire feed overload. XX indicates

 

time remaining in seconds before unit resets

 

automatically. See sections on Routine

 

Maintenance, Periodic Maintenance, and

 

Troubleshooting Guide Problem 17.

EP

Indicates problem in EPROM assembly. See

 

Troubleshooting Guide Problem 17.

uP

Indicates problem in microprocessor RAM.

 

See Troubleshooting Guide Problem 17.

EXX

Indicates various system problems. XX will

 

be a number from 01 to 10. Turn off power to

 

feeder. Wait 5 seconds. Turn power back on.

 

If error persists, see section on

 

Troubleshooting Guide Problem 17. If error

 

does not reoccur, be sure to check all wire

 

feed speed, acceleration, and timer settings

 

before you proceed.

Er

EEPROM error. Usually occurs at power-up.

 

Indicates one or more of the recalled settings

 

is out of acceptable limits. Press any key to

 

return to normal operation. Be sure to check

 

all wire feed speed, acceleration, and timer

 

settings before you proceed.