Lincoln Electric 7FH manual

Models: 7FH 7F

1 44
Download 44 pages 7.82 Kb
Page 33
Image 33

PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

PROBLEM

 

 

POSSIBLE CAUSE

 

 

WHAT TO DO

 

 

 

 

 

 

 

 

 

 

 

 

 

14. Cold Feed key does not turn

 

 

a. Defective keypad or Display PC

 

 

a. Check continuity between sockets 4

 

 

 

on wire feed motor but trigger

 

 

board is defective.

 

 

and 1 of keypad connector when

 

 

 

closure does.

 

 

 

 

 

Cold Feed key is closed. If not,

 

 

 

 

 

 

 

 

 

then replace keypad, otherwise,

 

 

 

 

 

 

 

 

 

replace Display PC board. (See

 

 

 

 

 

 

 

 

 

Procedure for Replacing PC

 

 

 

 

 

 

 

 

 

boards).

 

 

 

 

 

 

 

 

 

 

 

 

 

15. Display and/or indicator lights

 

 

\a. Defective keypad or Display PC

 

 

a. Ring out keypad. Replace if

 

 

 

do not change when the arrow

 

 

board.

 

 

defective. If not, then replace

 

 

 

or select keys are pressed.

 

 

 

 

 

Display PC board. (See Procedure

 

 

 

 

 

 

 

 

 

for Replacing PC boards.)

 

 

 

 

 

 

 

 

 

 

 

 

 

16. Display does not change when

 

 

a. Make sure that the function

 

 

a. Press the function key to light the

 

 

 

WFS and/or Volts/Trim knobs

 

 

select key has been pressed to

 

 

LED next to the display function that

 

 

 

are turned.

 

 

light the LED corresponding to

 

 

corresponds with the knob to be

 

 

 

 

 

 

the Volts/Trim or WFS display

 

 

adjusted.

 

 

 

 

 

 

depending on which knob you

 

 

 

 

 

 

 

 

 

are attempting to adjust.

 

 

 

 

 

 

 

 

 

b. Broken harness wire(s) or

 

 

b. Check harness connections to

 

 

 

 

 

 

harness disconnected from

 

 

encoder and control boards and

 

 

 

 

 

 

encoder boards(s) or control

 

 

continuity between corresponding

 

 

 

 

 

 

board.

 

 

harness leads in P2 and P17.

 

 

 

 

 

 

 

 

 

(Refer to wiring diagram).

 

 

 

 

 

 

c. Defective Encoder boards and/or

 

 

c. If b. is not the problem and neither

 

 

 

 

 

 

control board.

 

 

the WFS or Volts/Trim knobs are

 

 

 

 

 

 

 

 

 

properly adjusting then replace the

 

 

 

 

 

 

 

 

 

control board. If one of the two

 

 

 

 

 

 

 

 

 

knobs are properly adjusting, plug

 

 

 

 

 

 

 

 

 

the P17 harness from the working

 

 

 

 

 

 

 

 

 

board into the nonfunctional board.

 

 

 

 

 

 

 

 

 

If the previously nonfunctional board

 

 

 

 

 

 

 

 

 

is now working, replace the control

 

 

 

 

 

 

 

 

 

board. Otherwise replace the

 

 

 

 

 

 

 

 

 

nonfunctional encoder board. (See

 

 

 

 

 

 

 

 

 

procedure for replacing PC boards).

 

 

 

 

 

 

 

 

 

 

 

 

 

17. Display is blank.

 

 

a. Power source is OFF.

 

 

a. Turn ON power source.

 

 

 

 

 

 

b. Feeder supply fuse or circuit

 

 

b. Check input cable and feeder unit

 

 

 

 

 

 

breaker at power source is blown

 

 

for short in 41 and 42 circuit. Check

 

 

 

 

 

 

or tripped.

 

 

for shorted motor. Replace fuse or

 

 

 

 

 

 

 

 

 

reset circuit breaker.

 

 

 

 

 

 

c. Display or Control PC board is

 

 

c. Observe LED mounted on Control

 

 

 

 

 

 

bad.

 

 

PC board. It should blink on and off

 

 

 

 

 

 

 

 

 

at a controlled rate of 1 second ON

 

 

 

 

 

 

 

 

 

and 1 second OFF. If so, then

 

 

 

 

 

 

 

 

 

replace Display PC board. If not,

 

 

 

 

 

 

 

 

 

replace Control PC board. (See

 

 

 

 

 

 

 

 

 

Procedure for Replacing PC

 

 

 

 

 

 

 

 

 

boards.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

Page 33
Image 33
Lincoln Electric 7FH manual